Receiver Configuration 

 

 

 

 
Audio Channels

 

DE-9P connector used as unidirectional analogue audio data port. Pin outs: 

 

PIN 

Acronym 

Reference 

LEFT +  

Audio X Left + 

GND 

Ground 

AES + 

Digital Audio Output X + 

GND 

Ground 

RIGHT + 

Audio X Right + 

LEFT - 

Audio X Left - 

GND 

Ground 

AES - 

Digital Audio Output X - 

RIGHT - 

Audio X Right - 

 

Relay Channels 

DA-15P (male) connector used as for 4 Form C relays. Pin outs: 

PIN 

Acronym 

Reference 

RX (not used) 

RS–232 Receive 

Relay 1 NO 

NO Form C Lock 1 

Relay 2 NO 

NO Form C Lock 2 

Relay 3 NO 

NO Form C Lock 3 

Relay 4 NO 

NO Form C Lock 4 

GND  

Ground 

Relay 1 NC 

NC Form C Lock 1 

Relay 2 NC 

NC Form C Lock 2 

TX from receiver to PC 

RS-232 Transmit 

10 

Relay 1 Com 

Form C Common 1 

11 

Relay 2 Com 

Form C Common 2 

12 

Relay 3 Com 

Form C Common 3 

13 

Relay 4 Com 

Form C Common 4 

14 

Relay 3 NC 

NC Form C Lock 3 

15 

Relay 4 NC 

NC Form NC Form C Lock 4 

Manual Channel Change Procedure 

Содержание SFX3102

Страница 1: ...Technical Manual July 2017 ...

Страница 2: ...on 7 Antenna Requirements 7 Unpacking Contents and Set up 8 Receiver Preparation and Authorisation 8 Receiver LCD Display Options 10 Audio output ports 10 Control Ports 11 News Maker 12 Time Source 12 Receiver Configuration 13 Audio Channels 13 Relay Channels 13 Manual Channel Change Procedure 14 Troubleshooting Guide 15 Dish Alignment Checks 15 Procedure for Returning Equipment 16 ...

Страница 3: ...sation Main carrier downlink frequency 12293 7500 MHz Circuit ID FFXD001 Modulation QPSK 2 3 Standard DVB S2 Symbol rate 1548 9Ksym International Datacasting SFX3102F PRO AUDIO Norsat PLL LNB recommended stability 25 kHz or better Intermediate Frequency 993 75 NCC PID 4151 DVB S2 Transport Stream 1 ...

Страница 4: ...uled broadcast of material It is a common practice to power remote control systems with alternative power sources having mains isolating features such as UPS It is recommended that the receiver be powered from an uninterruptible power supply WARNING OPERATION OF ELECTRONIC EQUIPMENT INVOLVES THE USE OF VOLTAGES AND CURRENTS WHICH MAY BE DANGEROUS TO HUMAN LIFE OPERATING PERSONNEL SHOULD OBSERVE AL...

Страница 5: ...ge to GREEN LOCK LED will illuminate RED CONTROL LED will be OFF AUDIO 1 will be GREEN AUDIO 2 will be GREEN 5 Power down the Receiver If any of the above steps fail contact Macquarie Media Syndication Step 2 Rack mount the Receiver connect the antenna feed and power up 1 After 2 minutes the STATUS LED will change to GREEN LOCK LED will be GREEN CONTROL LED will BLINK GREEN AUDIO 1 will be GREEN A...

Страница 6: ... Quality delivery Lower overheads Less equipment wear and tear Less maintenance The Satellite System Offers Digital 20 kHz stereo delivery Circuit assigning start stopping recording for pre fed material Data transmission for AAP news copy Improved efficiency and increased program flexibility Full localism on network IDs sweeps jingles etc Satellite Equipment SFX3102 Pro Audio Receiver excluding GS...

Страница 7: ...tc The Receiver also provides 4 relay contact closure outputs to control station equipment for local insertion of material into program presentations The system provides the News Maker wire service which is supplied to authorised recipients through the RS 232 Receive Pin 1 on channel 2 relay connector The receivers also have the ability to replay forward and store content via the Ethernet ports on...

Страница 8: ... the Green Check button twice 7 Use the up or down arrow buttons to change the value and use the left or right arrow buttons to move the cursor left or right Change the frequency to 0993 750000 Press the green check mark button to accept the frequency 8 Press the right arrow to enter the Rate menu Enter the carrier symbol to 01548 900 9 Press the right arrow to enter the Mod standard menu Select M...

Страница 9: ...9 When the LOCK LED is steady on GREEN contact Macquarie Media Syndication to confirm authorisation and test the receiver If the LOCK LED flashes between RED AND GREEN or is steady on RED check the antenna system Authorisation will be indicated by the CH1 and CH2 Audio LED s FLASHING GREEN LED Display Lock indicates receivers lock to incoming satellite DVB carrier on the L Band input Off no power ...

Страница 10: ...ked it should start flashing to indicate its receiving and decoding commands Audio 1 and 2 provides indication of the authorization and audio decoding activity on the audio outputs When the receiver is locked to an audio stream these lights will flash green this is not an indication of the audio level as the lights will flash even when the audio is silent Audio levels can be viewed from the menu o...

Страница 11: ... 10 View Uncorr Biterbi Displays the of uncorrected errors received Normal 10 Status 11 Signal Level Displays as a the signal level Normal 20 80 Status 12 Sat 0 MAC Address Displays the MAC address of the receiver card Receiver Menu Stream 1 2 Relay 1 2 Meta data 1 2 Audio Meters 1 2 C N Uncorr Errors Signal Level SAT 0 MAC Carrier A B Freq MHZ Rate KYSM Sec MOD Standard NCC PID 22k Tone Polarisat...

Страница 12: ...supply high quality program material which is as close to the original as possible Tailoring of the audio signal to achieve a preferred sound is left to the receiving station Users will need to provide external means for level adjustment if required Clipping level at the receiver output is 16dBu For maximum flexibility Macquarie Media Syndication recommends you use stereo audio distribution amplif...

Страница 13: ...re configured as follows Relay Schedule Command Schedule Event 1 1 Commercial Start 2 2 Weather Start All News End 3 3 Sports Credit Special Event Credit 4 4 Station ID Station IDP Other Service Name RS232 RX Text News Maker For stations taking live programs that include news the news ID should be hard timed News Maker The News Maker service is supplied to authorised users via the serial data faci...

Страница 14: ...TECHNICAL OPERATIONS August 2014 14 Time Source The receiver is pre configured to send NTP packets from Ethernet Port 0 ETH0 ...

Страница 15: ...A 15P male connector used as for 4 Form C relays Pin outs PIN Acronym Reference 1 RX not used RS 232 Receive 2 Relay 1 NO NO Form C Lock 1 3 Relay 2 NO NO Form C Lock 2 4 Relay 3 NO NO Form C Lock 3 5 Relay 4 NO NO Form C Lock 4 6 GND Ground 7 Relay 1 NC NC Form C Lock 1 8 Relay 2 NC NC Form C Lock 2 9 TX from receiver to PC RS 232 Transmit 10 Relay 1 Com Form C Common 1 11 Relay 2 Com Form C Comm...

Страница 16: ...n press the Green Check Key once The receiver will now display 4 asterisks Press the Red X button once 4 Arrow down until reaching Audio Player 1 or Audio Player 2 depending on which channel you want to change then press the Green Check button twice 5 Scroll up or down to the required channel 6 Press the Green Check Key once 7 The receiver is now on the selected channel If your receiver is not aut...

Страница 17: ...liate stations are always notified during Sun transit season Rain fade Heavy rain can block the signal The fade can occur either at the uplink or the receiving site Rain fade can have more of an effect on poorly aligned small dishes or in systems where the signal is otherwise attenuated If you are experiencing problems it means either 1 you have faulty equipment 2 you are experiencing rain fade or...

Страница 18: ...hased The warranty commences from the date of delivery For faulty equipment covered by the warranty notify us on 02 8570 0301 Equipment Not Under Warranty For equipment not covered by warranty we will arrange for the pick up and repair of the faulty equipment and delivery of a replacement unit Notify us on 02 8570 0301 Cost of repair and freight charges will be added to your company s account ...

Отзывы: