TYPE 3 - wiring DiAgrAM
Page 7 of 12
ADS-DL-CH6
20100810
install guide
guides Français disponibles au www.idatalink.com
www.idatalink.com/support
automotive data solutions inc. © 2010
Doorlock Interface
Chrysler/DoDge/Jeep
1 2 3 4 5 6
CONNECT EITHER
IDATALINK
OR
STANDARD WIRING
IDATALINK (RS232) PORT REQUIRED
ON REMOTE STARTER. IF UNAVAILABLE
USE STANDARD WIRING METHOD
LEGEND
Wiring connections not required
when installed in iDatalink mode
* Wiring connection not required in
2-way iDatalink
LOCK/ARM (-) INPUT - GREEN/BLACK
UNLOCK (-) INPUT - BLUE/BLACK
TRUNK (-) INPUT - RED/WHITE
DISARM (-) INPUT - BROWN
(NC) PURPLE/YELLOW
(NC) PURPLE/BLACK
(NC) WHITE
(NC) BLACK/WHITE
DOOR & TRUNK STATUS (-) OUTPUT - GREEN
TACH OUTPUT (AC) - PURPLE/WHITE
BROWN/RED (NC)
BROWN/YELLOW (NC)
ORANGE/BLACK - GROUND
ORANGE/WHITE (NC)
ORANGE - DATA (J1850)
PINK/BLACK (NC)
PINK - IGNITION (+) INPUT
YELLOW/BLACK (NC)
YELLOW/RED (NC)
YELLOW - ANALOG OUTPUT
GROUND-OUT WHEN RUNNING (-) - BLUE/WHITE
(NC) NO WIRE
GROUND - BLACK
12V - RED
REFER TO WIRING
CROSS-REFERENCE CHART
IDATALINK
WITH OEM ALARM ONLY
IGNITION
WHITE (NC)
WHITE/RED
WHITE/BLACK
J1850
SKIM
IMMOBILIZER MODULE
REMOTE
STARTER
OR
SECURITY
SYSTEM
OR
KEYLESS
ENTRY
Doc. No.: ##3737##