TYPE 4 - wiring DiAgrAM
Page 8 of 12
ADS-DL-CH6
20100810
install guide
guides Français disponibles au www.idatalink.com
www.idatalink.com/support
automotive data solutions inc. © 2010
Doorlock Interface
Chrysler/DoDge/Jeep
MOVE THE FOLLOWING ITEMS IN YOUR
SCHEMATIC WITH ALL LAYERS ON
USE THE FOLLOWING LAYER SPECIFIC ITEMS AS
WIRING AND TEXT TEMPLATES
1 2 3 4 5 6
IDATALINK (RS232) PORT REQUIRED
ON REMOTE STARTER. IF UNAVAILABLE
USE STANDARD WIRING METHOD
LEGEND
Wiring connections not required
when installed in iDatalink mode
* Wiring connection not required in
2-way iDatalink
LOCK (-) INPUT - GREEN/BLACK
UNLOCK (-) INPUT - BLUE/BLACK
TRUNK (-) INPUT - RED/WHITE
(NC) BROWN
LEFT SLIDING DOOR (-) INPUT - PURPLE/YELLOW
RIGHT SLIDING DOOR (-) INPUT - PURPLE/BLACK
(NC) WHITE
(NC) BLACK/WHITE
DOOR & TRUNK STATUS (-) OUTPUT - GREEN
TACH OUTPUT (AC) - PURPLE/WHITE
BROWN/RED (NC)
BROWN/YELLOW (NC)
ORANGE/BLACK (NC)
ORANGE/WHITE (NC)
ORANGE - DATA (J1850)
PINK/BLACK (NC)
PINK - IGNITION (+) INPUT
YELLOW/BLACK (NC)
YELLOW/RED (NC)
YELLOW - ANALOG OUTPUT
GROUND-OUT. WHEN RUNNING (-) - BLUE/WHITE
(NC) WHITE
GROUND - BLACK
12V - RED
CONNECT EITHER
IDATALINK
OR
STANDARD WIRING
IDATALINK
IGNITION
PINK/WHITE
WHITE (NC)
WHITE/RED
WHITE/BLACK
WHITE/VIOLET
J1850
SKIM
IMMOBILIZER MODULE
YELLOW (S)
VIOLET/BROWN (SWITCH MUX*)
RESISTOR
BETWEEN 180-210 0HMS
85
30
87
87A
86
KEY
PINK/WHITE (IG)
1N4001
DIODE
REMOTE
STARTER
OR
SECURITY
SYSTEM
OR
KEYLESS
ENTRY
BCM LOCATED UNDER
DRIVER SIDE DASH
AGAINST FIREWALL
WARNING:
MULTIPLE WIRES WITH THE SAME COLOR.
TEST WIRES AND VERIFY PINOUT POSITION.
10 11 12 13 14 15 16 17
18 19 20 21 22 23 24 25
26 27 28 29 30 31 32 33 34
1 2 3 4 5 6 7 8 9
PURPLE/GREEN
C3 - CONNECTOR
C5
C4
C3
C2
C1
21
*USE ISOLATED GROUND WHEN
RUNNING (-) STATUS OUTPUT FROM
REMOTE STARTER TO POWER
RELAY
Doc. No.: ##3737##