Input Duplex Mode (1K and 2K4)
1K
N.C Input Contact
N.C Tamper
V
-
Z
1
V
+
Z
2
Z
3
C
12VDC OUT
ZONE INPUT
1-4
2K4
N.C Input Contact
Input 1
Input 9
For example, when input 9 is assigned to the expander within Protege, inputs 1 and 9 immediately operate as a
duplexed pair. The duplexed pairs are:
⦁
Inputs 1 and 9
⦁
Inputs 2 and 10
⦁
Inputs 3 and 11
⦁
Inputs 4 and 12
⦁
Inputs 5 and 13
⦁
Inputs 6 and 14
⦁
Inputs 7 and 15
⦁
Inputs 8 and 16
Trouble Inputs
Each input expander can monitor up to 16 trouble inputs.
Trouble inputs are used to monitor the module status and in most cases are not physically connected to an
external input.
The following table details the trouble inputs that are configured in the system and the trouble type and group
that they activate.
Input Number
Description
Type
Group
ZXxxx:01-15
Reserved
None
None
ZXxxx:16
Module Offline
Module Offline
System
Replace 'xxx' with the appropriate address of the module that you are programming.