UL and ULC Installation Requirements
Only UL / ULC listed compatible products are intended to be connected to a UL / ULC listed control system.
UL/ULC Installation Cabinet Options
Electronic Access Control System Installations
Cabinet Model
UL/ULC Installation Listings
EN-DIN-12
UL294, UL1076, ULC-ORD-C1076-86, CAN/ULC-S319
EN-DIN-24
EN-DIN-24-ATTACK
P
UL
ULC
All cabinet installations of this type must be located
inside the Protected Area
.
Not
to be mounted on the exterior of a vault, safe or stockroom.
All cabinet internal covers and lids/doors must be connected to the cabinet's main ground point for electrical
safety and static discharge protection.
CAN/ULC-S319
⦁
The Protege controller and reader expander module are intended to be mounted within the enclosure (refer to
UL/ULC Installation Cabinet Options), installed inside the protected premise, and are CAN/ULC-S319 Listed for
Class I applications only.
⦁
Exit devices and wiring must be installed within the protected area.
⦁
For the Protege controller and reader expander module, all RS-485 and reader terminal connections must be
made using shielded grounded cable.
⦁
All readers must be connected with shielded, grounded cable.
⦁
A bell or visual indicator used as an arming acknowledgment signal must be listed to a ULC security, signaling
or fire standard. If intended to be mounted outside, it must be rated for outdoor use.
⦁
Fail secure locking mechanisms shall only be installed where allowed by the local authority having jurisdiction
(AHJ) and shall not impair the operation of panic hardware and emergency egress.
⦁
If fire resistance is required for door assembly, portal locking device(s) must be evaluated to ULC-S533 and
CAN/ULC-S104.
⦁
Must be installed with CAN/ULC-S319 listed portal locking device(s) for ULC installations.
⦁
If a flexible cord is used to connect to line voltage, strain relief must be provided for the cord inside the
enclosure or at the knockout.
⦁
The power supply is not intended to be mounted on the exterior of vault, safe, or stockroom.
UL294
⦁
The Protege controller and reader expander module are intended to be mounted within the enclosure (refer to
UL/ULC Installation Cabinet Options), installed inside the protected premise, and are UL 294 Listed for Attack
Class I applications only.
⦁
Exit devices and wiring must be installed within the protected area.