C4 is handlebar function setting, the setting range is 0-4, press
button
(UP)
or
button (
DOWN
) for selection.
C4 parameter definition table
:
C4 value
P4=0
P4=1
0
zero startup handlebar
Non-zero startup handlebar
1
Zero startup, handlebar speed limit is
6Km/h
Before power assist, the handlebar speed limit is
6Km/h, after power assist, handlebar is full speed.
2
Zero startup, handlebar speed limit is
specified
Non-zero startup, handlebar is specified speed
limit.
3
Zero startup, Zero gear effectively
Before power assist, the handlebar speed limit is
6Km/h, after power assist, handlebar is full speed.
Stop power assist,
return the handlebar speed limit
is 6Km/h.
4
Handlebar gears is distinguished
according to the display meter.
Non-zero startup handlebar, Handlebar gears is
distinguished according to the display meter.
5
Retain
Retain
When C4 = 2 is confirmed, "specified speed limit value of handlebar" flashes,
press
(UP) button or
(DOWN) button for short to make selection, and the
default value is 20.
When C4 = 4 is confirmed, the "percentage value of the first gear speed accounts
for its full speed" of the power assist gear flashes, press
(UP) button or
(DOWN) button for short to make selection, and the default value is 50%. The
percentage values of other gears divide automatically in equal.
After finishing C4 parameter setting, press
button (SW) to save the current set
values and enter C5 parameter setting interface.
○
C5
Controller Maximum Current Adjustment Setting
Enter C5 parameter setting interface, C5 parameter column flashes.