![ICT KT-LCD10Y Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/ict/kt-lcd10y/kt-lcd10y_user-manual_3529665025.webp)
ELECTRIC BICYCLE METER KT
—
LCD10Y Product User Manual
- 23 -
original set parameters will be saved.
C Parameter Setting
After finishing P5 parameter setting, P5 parameter column stops flashing. Within 1
minute after stopping flashing, hold
button
(UP)
and
button
(DOWN)
for
about 2 seconds to enter C parameter setting environment.
○
C1 Power-Assist Sensor and Parameter Select Setting
Set C1 parameter first after entering C parameter setting environment, C1 parameter
column flashes.
C1 parameter setting interface
C1 is power-assist sensor and parameter select setting, its definition is shown in
following table. C1 setting ranges between 0-7, press
button
(UP)
or
button
(
DOWN
) for selection.
C1 parameter definition table
:
KUNTENG power assist
sensors
C1
value
Start
Sensitivity
KUNTENG V12
power assist sensors
C1
value
Start
Sensitivity
Forward 5 Signal
00
Standard
Reverse 6 Signal
05
Standard
01
Lower
06
Lower
02
Lowest
07
Lowest
Forward 8 Signal
00
Higher
Reverse 10 Signal
05
Higher
01
Standard
06
Standard
02
Lower
07
Lower
Forward 10 Signal
00
Highest
Reverse 12 Signal
05
Highest
01
Higher
06
Higher
02
Standard
07
Standard