background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1500W Sine Wave Series 

Inverter 

INSTRUCTION MANUAL 

855-151-000 

 

 

Innovative Circuit 

Technology Ltd. 

 

Models: 

ICT1500-12SW 

ICT1500A-12SW 

ICT1500-24SW 

ICT1500A-24SW 

ICT1500-48SW 

ICT1500A-48SW 

Содержание ICT1500-12SW

Страница 1: ...1500W Sine Wave Series Inverter INSTRUCTION MANUAL 855 151 000 Innovative Circuit Technology Ltd Models ICT1500 12SW ICT1500A 12SW ICT1500 24SW ICT1500A 24SW ICT1500 48SW ICT1500A 48SW...

Страница 2: ...lengths as short as practical Ensure battery voltage matches the rating of the model of inverter in use Carefully observe wiring polarity when making input connections Securely tighten all connections...

Страница 3: ...Switch Option T 10 TCP IP WEB BASED UTILITY OPTION 11 Status and Control 12 Device Setup 13 Network setup 14 E mail Setup 17 User Setup 18 Maintenance 20 MOBILE WEB APP 21 PASSWORD and IP ADDRESS RESE...

Страница 4: ...or low noise and long life Model Numbers and Options factory installed 115Vac 60Hz Models 230Vac 50Hz Models 1 Battery V Description ICT1500 12SW ICT1500 24SW ICT1500 48SW ICT1500A 12SW ICT1500A 24SW...

Страница 5: ...in the wiring box openings to be used for the installation as required The inverter must be installed in a restricted access environment such as an enclosed equipment rack if the back panel wiring ju...

Страница 6: ...Figure 3 Approved Mounting Orientations Connect the chassis ground stud on the back panel to a reliable earth ground point Ensure the inverter switch is in the off position then connect the dc input...

Страница 7: ...ely cord connected devices may be directly plugged in to the AC outlets located on the inverter front panel On units with the Transfer Relay option T connect the external AC power source grid power or...

Страница 8: ...Check that all connections to the inverter are correct and tight then tighten the wire strain relief clamps in the wiring junction box if used and install the wiring box cover Set the external batter...

Страница 9: ...ion only is above set limit and is powering the output Enabled ON DC Undervoltage Warning Triggers when Input Voltage drops below 11 0 22 0 44 0VDC for 1 s Clears when input is above 11 2 22 4 44 8V f...

Страница 10: ...n T The automatic AC transfer switch ensures that your load is primarily powered from the AC grid or generator when available and is quickly transferred to the battery powered inverter output should t...

Страница 11: ...monitoring and control of the inverter via the on board graphical web interface using any standard web browser such Microsoft Explorer Google Chrome or Mozilla Firefox To connect with your networked i...

Страница 12: ...ntrol This page provides information on the input battery voltage the inverter output voltage and power whether the AC output is provided by the inverter or an external AC source units with the option...

Страница 13: ...l cause the unit to periodically ping up to two remote IP addresses to verify the network connection status If there is no response from either address the unit will cycle the inverter output power Th...

Страница 14: ...Ensure this time is greater than the normal start up time for the network hardware to prevent nuisance power cycle events at system start up Reset Delay Enter the time 10 to 240 seconds that the inve...

Страница 15: ...to different networks Primary DNS Specify the IP address of the Primary DNS Server for your network Secondary DNS Specify the IP address of the Secondary DNS Server for your network Web Server CAUTION...

Страница 16: ...cribed in a MIB Management Information Base file which can be downloaded from the inverter s Help page The unique inverter MIB file must then be imported into your external SNMP management software En...

Страница 17: ...ations directly from the inverter The information required for this is available from your Network Administrator or Internet Service Provider ISP Figure 10 E mail Setup Page E mail SMTP Server Enter t...

Страница 18: ...figured for example E mail Notifications Select these options to receive an e mail when one or more of these events occurs An inverter failure occurs Check this box to receive an e mail notification w...

Страница 19: ...etails Select a User to Edit Choose which of the two user accounts to edit Administrator user name admin This account has full access to the inverter settings Standard User user name user This account...

Страница 20: ...other settings are maintained Restore Factory Default Settings Clicking the Restore button will restore ALL settings to the original factory default values including the user passwords To only restore...

Страница 21: ...the Mobile Web App or use a Virtual Private Network VPN connection Mobile Web App A shown above the Mobile Web App provides information on Battery Voltage Inverter Output Voltage Inverter Output Power...

Страница 22: ...ort number that the inverter is using in the Start and End fields The default HTTP port for the inverter is 80 c Select Both under Protocol TCP and UDP d Enter the local IP address of the inverter e g...

Страница 23: ...uter s WAN IP address may change from time to time without warning depending on your ISP In this case you should obtain a Static IP address from your ISP it will not change which will ensure more pred...

Страница 24: ...s cellnumber pcs rogers com Telus cellnumber msg telus com Virgin Mobile Can cellnumber vmobile ca TROUBLESHOOTING I am unable to access the web based configuration utility Check that you are using th...

Страница 25: ...I am not receiving e mails from the inverter Verify that the Send E mail checkboxes are ticked for any alarm conditions for which you wish to receive e mail notifications Verify your e mail settings b...

Страница 26: ...no options Switched Off Power Draw 15mW Output Frequency 115Vac models 60Hz 0 2Hz Output Frequency 230Vac models 50Hz 0 2Hz Output Voltage 115Vac models 115Vac 5Vac Output Voltage 230Vac models 230Va...

Страница 27: ...mply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is ope...

Страница 28: ...als accurately describe ICT product specifications and capabilities at the time of publication However because of ongoing improvements and updating of ICT products ICT cannot guarantee the accuracy of...

Отзывы: