Chapter 4: Wash Configuration
Wash Settings
The Wash Settings menu option is where important information about the user’s specific car wash equipment
is programmed. Important features such as the anti-theft program and Wet Down options are set in this menu.
The following is a list of menu items within the Wash Settings menu option and a brief explanation of their
function.
Wash Setting Field
Description
EqptMeasurement
InInches
If
Y
for yes, the equipment distance measured in inches. If
N
for no, the
equipment distance is measured in pulses.
Pulse Length
Pulse length must be set and will affect the input for Min and Max Car
Length as well as Anti Bounce settings. Enter “1” if the user wishes the system
to track start/stop times in pulses. Enter the number of inches of chain travel
for one pulse if the user wishes to set start/stop times in inches.
Pulse On Input 8
Is the Pulse Wiring installed on Input8? Enter
Y
for Yes and
N
for No. Default
is set to
Y
on the Mandatory Only Secondary Tunnel Master® Jr.
Min Car Length
The length in inches or the number of pulses of the minimum size vehicle
that may enter the car wash.
This can be as little as 24” but must be greater than the minimum pulse
length and greater than the anti- bounce value. This is part of the anti-theft
features.
Note: If using inches, when an entry is made the system will round off to the
closest setting possible based on the entry made.
Max Car Length
The length in inches or the number of pulses of the longest vehicle that will
enter the car wash before a violation is recorded. This is part of the anti-theft
feature.
NOTE:
If using inches, when an entry is made the system will round off to
the closest setting possible based on the entry made.
Anti-bounce
The length in inches or the number of pulses that the system still counts
a vehicle if the sensor drops out as car passes the gate switch for less than
anti-bounce value and comes back on. Value MUST be less than value set for
Min Car Length.
NOTE:
If using inches, when an entry is made the system will round off to
the closest setting possible based on the entry made.
Auto Pulse Period
This is the rate in which you want the conveyor to run when in Auto Pulse.
You should set this value to 0 when the conveyor is running. Doing this will
automatically calibrate this setting based on your conveyor speed. If you
change conveyor speeds, you should reset this.