![ICS Schneider Messtechnik induQ IVMI Series Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/ics-schneider-messtechnik/induq-ivmi-series/induq-ivmi-series_operating-manual_3525585031.webp)
— Series
IVMI
Technical data
Technical changes reserved
- 31 -
Type
I
VMI02
I
VMI07
I
VMI10
I
VMI20
Electrical characteristics
Supply voltage
12...24 VDC (±10 %)
for analogue output 0...10 V min. 16 VDC
24 VDC (±10%)
Current consumption
≤ 150 mA
Electrical connection
5-pin-plug M12x1
Degree of protection
(EN 60529)
IP 65 and IP67 (with attached coupling socket)
Process variables
Medium to measure:
Water and other conductive liquids
- Conductivity
> 50 μS/cm
- Temperature
-20…90 °C
Ambient temperature
-10…T
max
°C (
p. 32)*
Nominal diameter
DN 2
DN 7
DN 10
DN 20
Nominal pressure
PN 16
Process connection
G¼-ISO 228 male G½ - ISO 228
male
G½ - ISO 228 male
• G¾ - ISO 228
male
G1 - ISO 228
male
* The maximum ambient temperature depends on the temperature of the medium and the wiring of
the
IVMI
.
8.2 Materials table
Component
Material
Wetted
component
Housing
Aluminium die casting
Measuring tube
PEEK-GF30
X
Electrodes
Stainless steel 1.4571
X
Gaskets
EPDM • FKM (optional)
X
Process connections
Stainless steel 1.4571
X
Содержание induQ IVMI Series
Страница 50: ...S ries IVMI 50 Ba_IVMI 11 2021...
Страница 51: ...S ries IVMI Sous r serve de modifications techniques 51...
Страница 52: ......