![ICS Schneider Messtechnik induQ IVMI Series Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/ics-schneider-messtechnik/induq-ivmi-series/induq-ivmi-series_operating-manual_3525585026.webp)
Electrical connection
— Series
IVMI
- 26 -
• Ba_
IVMI
• 11/2021
4.1 Wirings
Pinout
The pinout differs according to the chosen configuration of the device.
M12x1
Possible pinout:
Pin 1:
+U
B
Pin 2: d. n. c. (do not connect) / Analogue U/I
Pin 3:
GND
Pin 4: Frequency
Pin 5: n. c. (not connected)
Connect the connecting cable according to your version and the pinout on the type plate.
Supply voltage
IVMI
with frequency output
Push-Pull
NPN Open Collector
PNP Open Collector
*1: Push-Pull switching outputs of several
IVMI
may not be connected in
parallel.
*2: Recommendation Pull-Up / Pull-Down resistance R
L
~5 k
Ω
Use of frequency and analogue output
Push-Pull
NPN Open Collector
PNP Open Collector
Recommendation for resistance R
L
~5 k
Ω