![background image](http://html.mh-extra.com/html/icpdas/pds-811/pds-811_user-manual_614813082.webp)
Programmable Device Server with I/O Expansion Slot(s)
PDS-8x1 Series User Manual, Version 1.1.2, Apr. 2015
-
82 -
6.3.8
M
This command is used to query or set the echo mode.
Effect:
Immediate
Command
Arguments
Description
M
Queries the echo mode settings.
M
= 0
Sets the Multi-echo mode to enable.
When set to multi-echo mode, the PDS-8x1 echoes data from a
device to all clients that are connected.
M
= 1
Sets the Single-echo mode to enable.
When set to single-echo mode, the PDS-8x1 echoes data from a
device to the client that requested the service.
M
=2
Sets the Half-Save Mode to enable.
If only one client connects to the PDS-8x1 controller, the
operation mode same as M0 mode; and if there are two or more
clients connecting to the PDS-8x1 controller, the operation
mode same as M1 mode.
Figure 6-3.8:
The following is an example of a
M
configuration.