IR-712A Universal IR Learning Remote Module (Ver. 1.3, Aug/23/2016) 34
When the IR learning process is finished, it is advised to save these learning data into
a file for backup by clicking Menu [File]-[Save IR Commands to File]. Besides, it is
necessary to download these learned IR commands to the IR-712A by selecting Menu
[Download]->[Download IR Commands to IR-712A].
4.4 Saving the Learned IR Commands to a File
Click Menu [File]->[Save IR commands to file] to save the learned IR commands as a
file. The extension of the file name is *.ird.
4.5 Download the IR Learning Commands to the IR-712A
After the learning IR command procedure or loading learning data from the file, it is
necessary to download these learning data to the IR-712A by clicking Menu
[Download]-> [Download IR Commands to IR-712A] in the menu and a progress
window will pop up as shown in figure 4-7.
Figure 4-7
Download the learned IR command to the IR-712A.
4.6 Test the IR commands saved in the IR-712A
The
“Test IR Commands in IR-712A” section can help users to test the learned IR
commands saved in the IR-712A as shown in figure 4-8. By clicking
“Transmit from IR-
712A
” button, the specified IR command (the prefix no. mentioned in 4.2) would be
emitted from the selected output channel of the IR-712A. You can check if the learned
IR command is correct in this way.
At the same time, the Modbus RTU command (last two bytes are CRC16 code) sent to
IR-712A is shown in the textbox underneath. This Modbus message is a reference for
users to help program the application to control IR-712A. The
“Show” button will show
the Modbus RTU message in the textbox without sending the Modbus command.