IR-712A Universal IR Learning Remote Module (Ver. 1.3, Aug/23/2016) 31
4. Learning IR command Example
After the establishment of the RS-232/485 wire connection between the PC and the
IR-712A, please follows the sections below to learn how to configure the IR-712A,
learn IR commands from remote controls and save the IR commands in PC and IR-
712A.
4.1 IR-712A Communication settings
The default serial communication parameters of the IR-712A are listed in Table 4-1:
Table 4-1
Default settings for IR-712A serial communication.
Item
Default
COM port
RS-232
(*)
Baud rate
115200 bps
Parity
None
Data bits
8
Stop bits
1
Modbus ID
1
* Note
: Please refer to the section 2-4.
In the section of
“Open / Close COM port”, select the serial communication parameters
of the host PC in the six combo boxes. Then, click
“Open” button to open the COM
port of the host PC. Notice that the Baud Rate, Parity, Data Bits, Stop Bits and Net ID
in the utility should be the same as those in the IR-712. Please click Menu [Setting]-
>[IR-712A Basic Settings] and refer to section 3.2.1 to change the serial
communication settings in the IR-712A.
Figure 4-1
Open the COM port of the Host PC.