73
Array No RAID Mode Total Drv Capacity(MB) Status
Array 1 Stripe 2 16126 Functional
Stripe Block: 64 KB
[ Drive Assignments ]
Channel:ID Drive Model Capacity (MB) Assignment
1 : Master QUANTUMCR8.4A 8063 Y
2 : Master QUANTUMCR8.4A 8063 Y
2. Confirm yes to the following warning message with the <Ctrl-Y> key
to continue array deletion:
Are you sure you want to delete this array?
Press Ctrl-Y to Delete, others to Abort
3. After deleting the array, you should create a new array using Auto
Setup or the Define Array menu from the FastBuild Main Menu.
74
Rebuilding A Mirrored Array
The Rebuild Array <5> Menu option is necessary to recover from an
error in a mirrored disk array. You will receive an error message when
booting your system from the FastTrak BIOS.
NOTE
: Drives MUST be replaced if they contain any physical errors.
Follow these steps BEFORE using the Rebuild Array menu option:
1. On bootup, the FastTrak100 Startup BIOS will display an error
message identifying which drive has failed.
2. Press <Ctrl-F> keys to enter FastBuild Main Menu.
3. Select submenu Define Array <3>.
4. Select the failed array and identify the Channel and ID of the failed
drive.
5. Power off and physically remove the failed drive.
6. Replace the drive with an identical model.
7. Reboot the system and enter the FastBuild Main Menu.
8. Select the <5> Rebuild Array option. The following screen will
appear.
FastBuild (tm) Utility 1.xx (c) 1995-2000 Promise Technology, Inc.
[ Rebuild Array Menu ]
Array No RAID Mode Total Drv Capacity(MB) Status
Array 1 Stripe 2 16126 Functional
Array 2 Mirror 2 8063 Critical
Array 3 —— —— —— ——
Array 4 —— —— —— ——
[ Keys Available ]