background image

 

45

Computer” followed by the System icon. 

2.

 Choose the “Hardware” tab, and then click the “Device 

Manager” tab. 

3.

 Click the “+” in front of “SCSI controllers.” “Promise 

Technology, Inc. FASTTRAK100 IDE controller” should appear. 
 

2-2 Microsoft Millennium 

2-2-1 Installing Drivers during Millennium Installation 

The following details the installation of the FastTrak100 drivers 
while installing Microsoft’s Millennium (with the FastTrak100 
controller card already in place). If you’re installing the 
FastTrak100 drivers on a system with Millennium already 
installed, see “Installing Drivers with Existing Millennium 
System.” 

1.

 Install Microsoft Millenium fully. 

2.

 After installation, go the “Start” menu and choose “Settings.” 

3.

 From the “Settings” menu, choose “Control Panel.” 

4.

 In the “Control Panel” window, double-click on the “System” 

icon. 

5.

 In the “System” window, choose the “Device Manager” tab. 

6.

 In the hierarchical display under “Other Devices” is a listing for 

“PCI Mass Storage Controller.” Choose it and then press the 
“Properties” button. 

7.

 Choose the “Driver” tab in the “Properties” window, choose 

“Update Driver,” and then press “Next.” 

8.

 Choose “Search for a better driver than the one your device is 

using now (recommended),” then press “Next.” 

9.

 Choose “Specify Location,” then type “A:\WINMILL” in the text 

box. 

10.

 Insert the “FastTrak100 Driver” diskette into drive A:. 

11.

 Press the “Next” button. A message informing you that 

Millennium has found “Windows Millennium Promise 
FASTTRAK100 (tm) IDE Controller” should appear. 

12.

 Press “Next,” then “Finish,” then “Yes” when asked if you 

want to restart your computer. Be sure to remove the diskette 
from drive A:. 
 

2-2-2 Installing Drivers with Existing Millenium System 

The following section details the installation of FastTrak100 
drivers on a system that has Millenium already installed and 

 

46

running. If you’re installing the FastTrak100 drivers on a system 
during an installation of Millenium, see “Installing Drivers During 
Millenium Installation.” 

1.

 After installing the FastTrak100 controller card and 

configuring the hard drives, power up the system and boot. 

2.

 The “Add New Hardware Wizard” will appear, informing you 

that it has found a “PCI Mass Storage Controller.” 

3.

 Click on “Next,” and from the generated list box, choose 

“Search for a better driver than the one your device is using 
now.” 

4.

 Click on “Next,” and from the generated choices, choose 

“Specify a location.” 

5.

 Insert the “FastTrak100 Driver” diskette in drive A:. 

6.

 Type “A:\WINMILL” in the text box that appears. 

7.

 Click on “Next.” A message informing you that Millennium has 

found “Windows Millennium Promise FASTTRAK100 (tm) IDE 
Controller” should appear. 

8.

 Click on “Next” and then on “Finish”. 

9.

 Choose “Yes” when asked if you want to restart your 

computer. 

Be sure to eject the diskette from drive A:. 

Confirming Driver Installation in Millennium 

To confirm that the driver has been properly loaded in 
Millennium, 
perform the following steps: 

1.

 Choose “Settings” from the “Start” menu. 

2.

 Choose “Control Panel,” and then double-click on the 

“System” 
icon. Choose the “Device Manager” tab, and then click the “+” in 
front of “SCSI controllers.” “Windows Millennium Promise 
FASTTRAK100 (tm) IDE controller” should appear. 

 

2-3 Windows 98 

5.2-3-1 Installing Drivers During Windows 98 Installation 

The following details the installation of the FastTrak100 drivers 
while installing Windows 98 (with the FastTrak100 controller 
card already in place). If you’re installing the FastTrak100 
drivers on a system with Windows 98 already installed, see 
“Installing Drivers with Existing Windows 98.” 

1.

 After installing the FastTrak100 controller card and 

configuring the hard drive(s) partition and format your hard 
drive(s), if necessary. 

Содержание ROCKY 3703EVR

Страница 1: ...ges This document contains proprietary information protected by copyright All rights are reserved No part of this manual may be reproduced by any mechanical electronic or other means in any form witho...

Страница 2: ...ors 17 3 7 USB Port Connector 19 2 3 8 IrDA Infrared Interface Port 19 3 9 CPU SYSTEM Fan Connector 19 3 10 LAN RJ45 STATE LED Connector 19 3 11 VGA Connector 19 3 12 ATA 100 IDE RATD Active LED Conne...

Страница 3: ...troller as a LAN controller Which is a fully integrated 10BASE T 100BASE TX LAN solution with high performance networking functions and low power features The ROCKY 3703EVR uses the advanced VIA PM133...

Страница 4: ...d for Flash Disk DiskOnChip application which will let users to use the Flash Disk with DOS command without any extra software utility Keyboard and PS 2 mouse connector A 6 pin mini DIN connector is l...

Страница 5: ...first the layout of ROCKY 3703EVR is shown and the unpacking information that you should be careful is described The jumpers and switches setting for the ROCKY 3703EVR s configuration such as CPU cloc...

Страница 6: ...e All shaded rows in tables of this manual are the default settings for the ROCKY 3703EVR 10 2 3 Setting the CPU of ROCKY 3703EVR JP8 CPU Multiplier Setting Speed 1 2 3 4 5 6 7 8 3 0 x CLOSE OPEN CLOS...

Страница 7: ...JP7 LAN2 JP10 Setting The onboard LAN controllers can be disabled if you don t want to use then All the hardware resource will be released After they are disabled JP7 JP10 DESCRIPTION CLOSE Enable OP...

Страница 8: ...IDE Disk Drive Connector CN5 CN6 You can attach four IDE Integrated Device Electronics hard disk drives on two channels These connectors support Ultra DMA100 IDE devices Non DMA100 devices are sugges...

Страница 9: ...8 IRQ4 CN3 COM2 2F8 IRQ3 16 Serial Port 10 pin Connector PIN NO DESCRIPTION 1 DATA CARRIER DETECT DCD 2 RECEIVE DATA RXD 3 TRANSMIT DATA TXD 4 DATA TERMINAL READY DTR 5 GROUND GND 6 DATA SET READY DSR...

Страница 10: ...DESCRIPTION 1 VCC 8 VCC 2 DATA 7 DATA 3 DATA 6 DATA 4 GROUND 5 GROUND 3 8 IrDA Infrared Interface Port CN24 The ROCKY 3703EVR has a built in IrDA port which supports Serial Infrared SIR or Amplitude S...

Страница 11: ...ach port supports 2 IDE devices at 100Mbps speed There are also one connector indicating the status of the IDE RAID channels 20 CN8 Channel 1 CN9 Channel 2 ATA 100 IDE RAID Connector 40 pin PIN NO DES...

Страница 12: ...e AMI BIOS setup program is designed to provide maximum flexibility in configuring the system by offering various options which may be selected for end user requirements This chapter is written to ass...

Страница 13: ...e refer to he following screen for this setup 24 For IDE hard disk drive setup please check the following possible setup procedure 1 Use the Auto setting for detection during boot up 2 Use the IDE HDD...

Страница 14: ...turn on off the Num Lock option on an enhanced keyboard when you boot If you turn it off the arrow keys on the numeric keypad can be used just as the other set of arrow keys on the keyboard and vice v...

Страница 15: ...ust AGP driving of signal AGP will have the best performance and compatibility 28 AGP Aperture Size to define the size of Graphics Aperture AGP Master 1 W S Write System will run single wait state del...

Страница 16: ...cify the power state of the hard disk after the specified period of hard drive idle has ended Standby Time Out Minute to specify the length of the system idle period while the system is in full power...

Страница 17: ...ransfer EPP supports devices that comply with the Enhanced Parallel Port specification 32 ECP supports devices that comply with the Extended Capabilities Port Parallel Port IRQ to assign certain IRQ t...

Страница 18: ...s installed in your computer or not You must specify the slot number on the board which will be used for the card Offboard PCI IDE Primary Secondary IRQ to specify the PCI interrupt that is assigned t...

Страница 19: ...activate the timer that will eventually time out and reset the CPU board To ensure that this reset condition won t occur the WatchDog Timer must be periodically refreshed by reading the same I O port...

Страница 20: ...r Port 1 3B0 3DF Standard AGP Graphic Adapter 3F0 3F7 Floppy Disk Controller 3F8 3FF Serial Port 1 443 Watch dog timer enable 843 043 Watch dog timer disable 38 1 st MB Memory Address Map Memory addre...

Страница 21: ...on switch to the CN29 power button And connect the power cable from Backplane to CN30 of CPU card If you want to turn ON the system just press the button once And if you want to turn off the power sup...

Страница 22: ...ing RAID 0 mirroring RAID 1 striping mirroring RAID 0 1 or spanning JBOD operation respectively With striping identical drives can read and write data in parallel to increase performance Mirroring inc...

Страница 23: ...on screen and then press the Enter key 6 The Windows 2000 Setup screen will appear again saying Setup will load support for the following mass storage devices The list will include Win2000 Promise Fa...

Страница 24: ...100 drivers on a system that has Millenium already installed and 46 running If you re installing the FastTrak100 drivers on a system during an installation of Millenium see Installing Drivers During M...

Страница 25: ...the generated choices choose Specify a location 5 Type A WIN95 98 in the text box that appears 6 Insert the FastTrak100 Driver diskette in drive A 48 7 Click on Next A message informing you that Wind...

Страница 26: ...ext box and then choose OK 8 When the Install Driver dialog box appears select WinNT Promise FastTrak100 tm Controller and then press OK 9 When the Select SCSI Adapter Option dialog box appears press...

Страница 27: ...l use your PC most under the Typical Application usage section the choices are A V Editing Server and Desktop the default 3 Press Ctrl Y keys to Save and create the array 4 Reboot your system 5 Once t...

Страница 28: ...already contains data and or is the bootable system drive in your system You will need another drive of identical or larger storage capacity WARNING Backup any necessary data before proceeding Failur...

Страница 29: ...alling Driver chapter on page 46 to install the FastTrak100 driver and or operating system 56 4 Using FastBuild Configuration Utility The FastBuildTM Configuration Utility offers several menu choices...

Страница 30: ...ation tips Arrow keys highlights through choices Space bar key allows cycling through options Enter key selects an option ESC key is used to abort or exit the current menu 58 Using the Main Menu This...

Страница 31: ...he disk array you are creating After making all selections use Ctrl Y to save selections FastBuild will automatically build the array FastBuild tm Utility 1 xx c 1995 2000 Promise Technology Inc Auto...

Страница 32: ...es Using a Hot Spare Drive If a third drive is attached as a Slave and is not assigned to a mirrored two drive disk array one optimized for Security it will be recognized as a Spare Drive Such a drive...

Страница 33: ...ally defining the drive elements and RAID levels for one or multiple disk arrays attached to FastTrak100 Users will commonly create one or two drive arrays with FastTrak100 though the card will suppor...

Страница 34: ...ndling e mail and other common server data The default is 64K 66 Assigning Drive s to Array 1 Under the Drive Assignments section highlight a drive using the Up keys 2 With the Space bar key change as...

Страница 35: ...After assigning the drives to a Mirroring array press Ctrl Y keys to save your selection The window below will appear Do you want the disk image to be duplicated to another Yes No Y Create and Duplica...

Страница 36: ...eing used as a secondary controller 1 Once you have returned to the Define Array Menu window below you will see the array s you have created You now may use the menu to select which previously defined...

Страница 37: ...nt FastTrak100 card connectors Since each drive s array data identifies itself to the array it is possible to move or swap drives without modifying the array setup This is valuable when adding drives...

Страница 38: ...sage when booting your system from the FastTrak BIOS NOTE Drives MUST be replaced if they contain any physical errors Follow these steps BEFORE using the Rebuild Array menu option 1 On bootup the Fast...

Страница 39: ...enable or disable the FastTrak100 BIOS from halting the default if it detects an error on boot up You may also view the system resources Interrupt and I O port address of FastTrak s data channels Fast...

Отзывы: