Table 9 – Air Delivery -- CFM (With Filter)
FURNACE
SIZE
SPEED
TAPS
Function
EXTERNAL STATIC PRESSURE (IN.W.C.)
0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00
0401410
Gray
Cooling. Do not use for heating
1120 1085 1055 1015 985
950
915
880
850
815
Yellow
Cooling. Do not use for heating
925
885
850
810
775
735
695
660
620
580
Blue
3
Heating or alt Cooling
765
725
685
640
605
565
525
475
430
375
Orange
3
Alt Cooling or alt Heating
750
710
665
625
585
545
500
455
405
350
Red
3, 7
Alt Cooling. Do not use for heating
510
435
400
345
290
230
190
145
---
---
0401712
Gray
Cooling. Do not use for heating
1120 1090 1055 1020 985
950
915
875
840
805
Yellow
Cooling. Do not use for heating
910
880
845
800
760
720
680
640
595
555
Orange
Alt Cooling or alt Heating
835
795
760
720
680
630
585
540
505
475
Blue
3
Heating or alt Cooling
740
700
660
610
565
520
475
440
405
365
Red
3, 7
Alt Cooling. Do not use for heating
555
500
445
395
350
315
260
205
---
---
0601412
Gray
Cooling. Do not use for heating
1165 1140 1110 1080 1035 1000 960
920
870
825
Blue
Heating or alt Cooling
1105 1085 1050 1010 975
930
890
845
795
755
Yellow
Alt Cooling or alt Heating
1040 1000 960
920
880
840
785
740
690
640
Orange
3
Alt Cooling or alt Heating
840
795
750
705
655
610
555
500
450
395
Red
3
Alt Cooling. Do not use for heating
745
615
555
510
450
390
340
290
230
195
0601714
Gray
Cooling. Do not use for heating
1335 1300 1275 1230 1190 1135 1090 1040 985
925
Yellow
Alt Cooling or alt Heating
1170 1135 1095 1045 995
940
890
825
770
700
Blue
3
Heating or alt Cooling
1010 965
910
855
800
735
675
615
555
505
Orange
3
Alt Cooling or alt Heating
960
905
855
800
740
675
615
555
505
460
Red
3
Alt Cooling. Do not use for heating
910
735
675
605
535
485
430
375
330
265
0801716
Gray
Cooling. Do not use for heating
1545 1505 1460 1420 1365 1320 1275 1225 1180 1135
Blue
Heating or alt Cooling
1375 1330 1275 1225 1175 1125 1075 1025 970
920
Yellow
3
Alt Cooling or alt Heating
1195 1140 1090 1040 985
930
875
815
765
705
Orange
3
Alt Cooling. Do not use for heating
1015 955
900
845
780
730
670
615
550
490
Red
3, 7
Alt Cooling. Do not use for heating
945
735
575
520
450
375
325
260
---
---
0802120
Gray
5, 6
Cooling. Do not use for heating
2020 1965 1920 1865 1815 1760 1705 1650 1595 1545
Yellow
Alt Cooling or alt Heating
1650 1590 1535 1475 1425 1370 1315 1260 1205 1145
Blue
Heating or alt Cooling
1495 1430 1365 1310 1260 1200 1145 1085 1030 970
Orange
Alt Cooling or alt Heating
1420 1355 1290 1235 1175 1120 1060 1005 945
890
Red
3
Alt Cooling. Do not use for heating
1200 1120 1060 995
940
875
810
750
685
625
1002120
Gray
5, 6
Cooling. Do not use for heating
2060 2010 1955 1905 1850 1800 1750 1690 1630 1565
Blue
Heating or alt Cooling
1730 1675 1620 1565 1510 1455 1385 1325 1270 1210
Yellow
Alt Cooling or alt Heating
1685 1630 1570 1515 1460 1410 1345 1280 1225 1170
Orange
3
Alt Cooling or alt Heating
1445 1370 1310 1250 1185 1115 1055 1005 950
875
Red
3
Alt Cooling. Do not use for heating
1235 1155 1090 1020 945
900
835
755
690
635
1202420
Gray
5, 6
Cooling. Do not use for heating
2070 2020 1965 1910 1850 1790 1725 1660 1605 1550
Blue
Heating or alt Cooling
1795 1735 1680 1620 1560 1495 1440 1375 1315 1255
Yellow
3
Alt Cooling or alt Heating
1465 1400 1340 1270 1210 1150 1090 1030 950
880
Orange
3
Alt Cooling. Do not use for heating
1295 1235 1165 1095 1030 970
905
825
760
700
Red
3
Alt Cooling. Do not use for heating
1095 1020 945
875
805
730
660
585
525
465
NOTE
:
1. A filter is required for each return---air inlet. Airflow performance includes a 3/4---in. (19 mm) washable filter media such as contained in a
factory---authorized filter rack. See accessory list in Specification sheet. To determine airflow performance without this filter, assume an additional 0.1 in.
w.c. available external static pressure.
2.
ADJUST THE BLOWER SPEED TAPS AS NECESSARY FOR THE PROPER AIR TEMPERATURE RISE FOR EACH INSTALLATION.
3. The “Function” column identifies with speed taps can be used for heating. Shaded areas indicate that this airflow range is
BELOW THE RANGE ALLOWED
FOR HEATING OPERATION. THESE AIRFLOW RANGES MAY ONLY BE USED FOR COOLING.
4. If the same motor speed tap is needed for heating and cooling, a Jumper Wire accessory kit is available, see Specification sheet for the current Jumper
Wire accessory part number. Reference the “Start---up, Adjustments, and Safety Check” section for further Jumper Wire instructions.
5. Airflows over 1800 CFM require bottom return, two---side return, or bottom and side return. A minimum filter size of 20” x 25” (508 x 635 mm) is required.
6. For upflow applications, air entering from one side into both the side of the furnace and a return air base counts as a side and bottom return.
7. The “---” entry indicates an unstable operating condition.