PARTS LIST

Model : ODH53F100LB-3MC, OCF105A12C

ITEM

DESCRIPTION

PART #

1

Complete heat exchanger

B30776-01

2

Top heat exchanger

B30542-01

3

Gasket, heat exchanger 

B30517

4

Hexagonal flange nut 3/8-16NC brass

F07O001

5

Combustion chamber

B30518

6

Bottom heat exchanger

B30757

7

Gasket panel, peep hole

B30753

8

Front filter draw er

B30507

9

Gasket, burner

B30534

10

Left side panel assembly

B30550-02

11

Left side panel insulation

B30571

12

Left filter support

B30566

13

Rear panel assembly

B30549

14

Rear panel insulation

B30572

15

Rear filter support

B30555

16

Rear Baffle

B30564

17

Division panel

B30567

18

Blow er slide support

B30513

19

Right side panel assembly

B30550-01

20

Right side panel insulation

B30571

21

Right filter support

B30566

22

Upper front reinforcer

B30556

23

Blow er door assembly

B30709-02

24

Door handle

Z99F050

25

Center front panel assembly

B30703

26

Center front panel insulation

B30570

27A

Front right baffle

B30569-01

27B

Front left baffle

B30569-02

28

Bottom front panel assembly

B30774

29

Bottom front panel insulation

B30773

30

Washer 3/8" AA zinc

F06F005

31

Hexagonal nut 3/8-16NC brass

F07F024

32

Washer panel, peep hole 

B30752

33

Hexagonal flange nut 3/8-16NC brass

F07O001

34A

5" breech plate

B30459

34B

3" breech plate

B30515

35

Gasket, breech plate 

B30415-02

36

Burner electrical kit

B30575

37

Corner conduit

B30557

38

Electrical box cover (w ithout logo )

B40098-02

39

Transformer 120/24 VAC / 40 VA 

L01F009

40

Terminal strip, 6 positions 

A00336

41

Electrical box

B30830

42

Relay SPDT 24VAC

L01H009

43

Rocker sw itch SPST (constant blow er operation)

L07F003

44

Terminal strip, 6 positions 

L05F011

45

Rocker sw itch SPST (main pow er)

L07F016

46

Thermosw itch 160-40F

R02N012

47

Thermosw itch 110-10F

R02N011

48

Blow er w eel GT10-10DD

Z01L002

49

Blow er GT10-10DD   (housing and w heel)

Z01I004

50A

Blow er assembly

B01405-01

50B

Belly band assembly (belly band & legs included)

B01888

51

Motor assembly 1/3 HP (motor, bell band & legs included)

B01890-01

52

Blow er electrical kit

B30096

53

Blow er side rails

B30433

54

Seal strip

B01291-01

55

Capacitor 5 MF 

L01I001

56

Capacitor holder

B01024

57

Fan limit control 11 1/2"

R02I002

58A

Peep hole kit

K30011

58B

Overfire pressure test kit

K30012

59

Gasket, glass  1.062 OD      

B30055

60

Glass, neoceram 1.031" DIA.      

B30041-01

61

Blocked vent shut off BVSO

Z06G001

62

External electrical kit BVSO

B03118-01

27

L50030A

445 01 4024 05

Содержание OCF105A12C

Страница 1: ...CING OF THE UNIT AND KEEP THE DOCUMENT NEAR THE FURNACE FOR FUTURE REFERENCE HOMEOWNER PLEASE KEEP THIS MANUAL NEAR THE FURNACE FOR FUTURE REFERENCE Printed in Canada Printed on 100 recycled paper OIL...

Страница 2: ...s and test instruments Failure to carefully read and follow all instructions in this manual can result in personal injury and or death property damage furnace malfunction WARNING Fire hazard The furna...

Страница 3: ...ions regarding any brand or type of detector CAUTION Ensure that the area around the combustion air intake terminal is free of snow ice and debris CAUTION An air pressure switch MUST be used when the...

Страница 4: ...ine or any other damaging chemicals Refer to Part 1 section 5 2 1 4 VENTING 1 4 1 General The furnaces can be vented in several ways Chimney Vented Using the Beckett AFG or Riello 40 F burner the furn...

Страница 5: ...ected to a 20 foot tall clay lined masonry chimney the thermal resistance of this type of chimney is R2 which is less than R6 The actual firing rate at 156 psig is 1 25 x 60 75 Therefore this table sh...

Страница 6: ...nal in accordance with all local and national codes The following requirements shall be considered to be minimum requirements that can be overridden by stricter local and national codes FIGURE 1 The v...

Страница 7: ...hat the band will close with an action of one strip sliding over the other not under the gear head of the draw clamp see Figure 1 8 Tighten the band clamp with considerable torque to cause the gum sea...

Страница 8: ...E BACK 5 THREAD SPIN SLEEVE BACK 10 CUT STAINLESS STEEL CORE BACK BY 3 9 FIGURE 1 3 FIGURE 1 4 FIGURE 1 1 FIGURE 1 2 FIGURE 1 5 FIGURE 1 6 INSERT STAINLESS STEEL CORE ONTO BREECH TUBE DRIVE THREE STAI...

Страница 9: ...IGURE 1 8 SEALANT FLOWING OUT FROM UNDER BAND CLAMP AT TERMINAL SEALANT OUTFLOW FIGURE 1 11 10 APPLY THE SEALANT TO THE TUBE END SEALANT OUTFLOW SEALANT FLOWING OUT FROM UNDER BAND CLAMP AT BREECH TWI...

Страница 10: ...TIGHTLY INTO RECESS INSTALL STABILIZER SHROUD CAULK TO SEAL STABILIZER SHROUD TO THE WALL FIGURE 1 13 FIGURE 1 14 FIGURE 1 12 VENT TERMINAL PRESSURE SWITCH REFER TO WIRING DIAGRAM FOR ELECTRICAL CONNE...

Страница 11: ...t 1 section 5 3 1 5 3 Outdoor Combustion Air Side wall Venting DV 2000 for a complete description 1 5 AIR FOR COMBUSTION WARNING Poisonous carbon monoxide gas hazard Comply with NFPA standards for the...

Страница 12: ...two plastics Intake pipe length DV 2000 The DV 2000 venting system has been certified for 37 equivalent m 120 equivalent feet of 3 intake pipe Count a 90 elbow as 10 equivalent feet and a 45 elbow as...

Страница 13: ...king Checking the air and turbulator settings Before starting the burner for the first time adjust the air and turbulator settings to those listed in Table 4 Once the burner becomes operational final...

Страница 14: ...e heat exchanger Wire the thermostat and condensing unit contactor as indicated in the wiring diagram Figure 6 1 9 4 Ductwork and Filter Installation Design and install the air distribution system to...

Страница 15: ...Fan Limit Control heats up to the factory set point the circulating air blower starts 7 The circulating air blower and burner motor remain on until the thermostat is satisfied Also the solenoid valve...

Страница 16: ...shut down for an extended period of time 4 Set thermostat higher than the room temperature 5 If the burner motor does not start or ignition fails turn off the disconnect switch and CALL A QUALIFIED SE...

Страница 17: ...flame should shut down before a 1 smoke reading occurs 3 Gradually block the vent outlet The burner flame should shut down before a 1 smoke reading occurs 4 If the burner does not shut down before 1...

Страница 18: ...ly from the front inspection port Also the furnace has external clean out ports so the soot does not fall into the fan compartment during the cleaning operation IMPORTANT Do not vacuum the ceramic cha...

Страница 19: ...een installed the burner will have to be removed to check the retention head 3 1 4 Nozzle Replace the nozzle with the one specified in Table 4 3 1 5 Oil filters Tank filter The tank filter should be r...

Страница 20: ...hone Day Night Dealer name and address START UP TEST RESULTS Nozzle Pressure lbpsi Burner adjustments Primary air Fine air Drawer Assembly CO2 Smoke scale Bacharach Gross stack temperature F Ambient t...

Страница 21: ...3 3 4 5 AFUE From CSA B212 standard and Canadian regulation 81 5 81 0 80 3 AFUE From ASHRAE 103 standard and US regulation 81 5 81 0 80 3 RIELLO BURNER SIDE WALL INSTALLATION Burner tube insertion len...

Страница 22: ...DNS 0589 Rev C FIGURE 5 Models ODH53F100LB 3MC OCF105A12C 23 445 01 4024 05...

Страница 23: ...24 FIGURE 6 Wiring diagram ODH53F100LB 3MC OCF105A12C 445 01 4024 05...

Страница 24: ...COMPONENTS AND REPLACEMENT PARTS 25 445 01 4024 05...

Страница 25: ...PARTS LIST Model ODH53F100LB 3MC OCF105A12C B50030A 26 445 01 4024 05...

Страница 26: ...gonal nut 3 8 16NC brass F07F024 32 Washer panel peep hole B30752 33 Hexagonal flange nut 3 8 16NC brass F07O001 34A 5 breech plate B30459 34B 3 breech plate B30515 35 Gasket breech plate B30415 02 36...