20
21
Flashing
sequence
Error
Solution
2 x short
Receiver undervoltage
(< 6.5V for > 1500ms)
Check and if necessary, increase
the power supply of the receiver.
3 x short
Receiver overvoltage
(> 36V for > 60ms)
Check and if necessary, reduce
the power supply of the receiver.
4 x short
Receive temperature
exceeded (> 85°C)
Disconnect the receiver’s power
supply and leave the receiver
to cool.
1 x long,
1 x short
Receiver output 1
(> 3.5A for > 1000ms)
Check and reduce the current
consumption of the connected
component.
1 x long,
2 x short
Receiver output 2
(> 3.5A for > 1000ms)
Check and reduce the current
consumption of the connected
component.
1 x long,
3 x short
Receiver output 3
(> 3.5A for > 1000ms)
Check and reduce the current
consumption of the connected
component.
1 x long,
4 x short
Receiver output 4
(> 3.5A for > 1000ms)
Check and reduce the current
consumption of the connected
component.
1 x long,
5 x short
Receiver output 5
(> 3.5A for > 1000ms)
Check and reduce the current
consumption of the connected
component.
Flashing
sequence
Error
Solution
1 x long,
6 x short
Receiver output 6
(> 3.5A for > 1000ms)
Check and reduce the current
consumption of the connected
component.
1 x long,
7 x short
Receiver output 7
(> 3.5A for > 1000ms)
Check and reduce the current
consumption of the connected
component.
1 x long,
8 x short
Receiver output 8
(> 3.5A for > 1000ms)
Check and reduce the current
consumption of the connected
component.
3 x long
Permissible total current
of receiver exceeded
(> 10A for > 1000ms)
Check and reduce the total
current consumption.
4 x long
Critical receiver error
Disconnect and reconnect the
receiver’s power supply. If the
error persists, contact the
service department.
Continuously
short
Critical transmitter error Switch off transmitter and
switch back on. If the error
persists, contact the service
department.
2 x long,
1 - 6 x short
Internal receiver error
Disconnect and reconnect the
receiver’s power supply. If the
error persists, contact the
service department.
5. ERROR CODES AND REMEDY
In the event of system malfunctions, the error that has occurred is
indicated by a flashing sequence (see “LED status” section) of the
status LED in red. The corresponding error can be diagnosed using
the following list and (where possible) remedied.
6. MAINTENANCE AND CLEANING
The transmitter is maintenance-free for the user. Maintenance and
repairs must be carried out by a qualified technician. The transmit-
ter may only be cleaned with a damp cloth and without chemicals,
| T
M600