- 22 -
3) How to fix installation plate
The wall you select should be strong and solid enough to prevent
vibration
1. Mount the installation plate on the wall with four
type A screws. If mounting the unit on a concrete
wall, use anchor bolts.
Mount the installation plate horizontally by
aligning the centerline using a level.
2. Measure the wall and mark the centerline. It is also
important to use caution concerning the location
of the installation plate-routing of the wiring to
power outlets is through the walls typically.
Drilling the hole through the wall for piping con-
nections must be done safely.
5-7mm
(0.2~0.3")
Indoor
WALL
Outdoor
Installation Plate
Type "A" screw
(+1 D4.0 L38.0 MSR3/FZW)
30K
Right rear piping
Left rear piping
50mm(2.0")
ø
70mm(2.76")
180mm
(7.2")
115mm(4.5in)
4) Drill a hole in the wall
■
Drill the piping hole with a ø70mm (0.76") hole
core drill. Drill the piping hole at either the right or
the left with the hole slightly slanted to the out-
door side.