ICP DAS USA Zigbee ZT-2060 Скачать руководство пользователя страница 5

 

ZT-2060 Zigbee 6-ch DI, 4-ch Relay Output Module

- QuickStart (Jan/2018)  

ICP DAS USA, Inc.

 

www.icpdas-usa.com

 | 1-310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717

 

 
 
 

 

Rotation Switch

 

 

   

 

0

 

  

1

 

 

2

 

 

3

 

  

……

 

  

F

 

  

Note

 

 

 

Address

 

 

SW

 

 

01

 

02

 

03

 

  

……

 

  

0F

 

  

MSB = 0

 

 

 

Node ID

 

 

SW

 

  

0x0001

 

 

0x0002

 

 

0x003

 

  

……

 

  

0x000F

 

  

 

 

 

  

 

 

  

  

    

 

 

   

 

0

 

  

1

 

 

2

 

 

3

 

  

……

 

  

F

 

    

 

 

Address

 

10

 

 

11

 

12

 

13

 

  

……

 

  

1F

 

  

MSB = 1

 

 

 

Node ID

 

 

0x0010

 

  

0x0011

 

 

0x0012

 

 

0x013

 

  

……

 

  

0x001F

 

  

 

 

 

  

 

 

  

  

    

 

 

 

Once the address of hardware switch is set to 0x00, it mens the address is using 
software configurations. Refer the more detailed information at Sec. 6.6 of user 
manual.

 

 

 

DIP Switch

 

Number

 

   

Item

 

 

Status

 

 

Explain

 

 

1

 

   

Address MSB

 

 

OFF

 

Valid Address (Node ID) from 0x00 to 0x0F

 

 

   

 

ON

 

 

Valid Address (Node ID) from 0x10 to 0x1F

 

 

 

 

   

 

 

 

2

 

   

Protocol

 

 

OFF

 

DCON Protocol

 

 

   

 

ON

 

 

Modbus RTUProtocol

 

 

 

 

   

 

 

 

3

 

 

Checksum

 

 

OFF

 

Disabled

 

 

 

 

ON

 

 

Enabled

 

 

 

 

   

 

 

 

4

 

 

ZigBee Pan ID

 

 

OFF

 

Pan ID = 0x0000

 

 

 

 

ON

 

 

Pan ID = 0x0001

 

 

 

 

   

 

 

 

5

 

    

 

OFF

 

------

 

 

     

 

ON

 

 

0x08

 

 

 

 

   

 

 

 

6

 

    

 

OFF

 

------

 

 

 

ZigBee

 

 

ON

 

 

0x04

 

 

 

 

 

 

 

 

 

RF Channel

 

 

 

 

 

7

 

 

 

OFF

 

------

 

 

     

 

ON

 

 

0x02

 

 

 

 

   

 

 

 

8

 

    

 

OFF

 

------

 

 

     

ON

 

 

0x01

 

 

 
 
 
 
 

Содержание Zigbee ZT-2060

Страница 1: ...igital input channels each of which features photocouple isolation In addition you can choose sink type or source type input via wire connections All channels are able to be used as 16 bit counters Th...

Страница 2: ...ters A Pan ID parameter is the group identity for a ZigBee network and must the same for all devices in the same ZigBee network Address Node ID parameter is the individed identity of a specific the Zi...

Страница 3: ...annel C Protocol Application Mode When implementing custom programs based on different protocols the following application modes are recommended in order to ensure communicatible User Program Protocol...

Страница 4: ...ies can be adjusted by using the external rotary switch and the DIP switches The ZT 2060 device should only be rebooted once the configuration is complete DIP Switch to the ZT 2042 ZT 2043 ZT 2060 ZT...

Страница 5: ...0x013 0x001F Once the address of hardware switch is set to 0x00 it mens the address is using software configurations Refer the more detailed information at Sec 6 6 of user manual DIP Switch Number It...

Страница 6: ...Please refert to documents shown below for full details of how to configure these devices Once configuration of the ZigBee coordinator has been completed Set the Pan ID and the RF Channel values for...

Страница 7: ...Configurations of ZT 2550 ZT 2570 Configurations of ZT 2000 I O Device 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 ON Number Item Status Explain 1 Address MSB OFF Address Node ID is 01 Rotation Switch...

Страница 8: ...control ICP DAS also provides the DCON Utility which can be used to simulate DCON Modbus communication This software can also be used to verify the device settings and ZigBee I O functions The DCON Ut...

Страница 9: ...ZT 2060 Zigbee 6 ch DI 4 ch Relay Output Module QuickStart Jan 2018 ICP DAS USA Inc www icpdas usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 9...

Страница 10: ...gram of the current DIP switch positions A copy of the configuration file for the ZT 2000 coordinator This file can be obtained using the procedure outlined below and should be attached to your email...

Страница 11: ...Weak Blinking 2s The Signal is Unstable or There is no Available The status of module board Steady Lit The Power is ON and the Module Initialization is Correct ZigBee PWR Blinking 200ms Module Initial...

Отзывы: