background image

TPD/VPD Series HMI Device User Manual

 

Copyright ©  2020 ICP DAS Co., Ltd. All Rights Reserved.                     

 

Page: 70 

 

3.3.2

 

PoE Power Supply 

When using PoE devices such as the TPD-283(-H)/283U(-H)/283(U)-Mx, TPD-433(-H)/433(-H)-EU/ 

433F(-H)/433-M2/703(-64) 

and 

VPD-133(N)(-H)/143(N)(-H)/173N(-64)/173X(-64), 

you 

can 

incorporate  the  ICP  DAS 

“PoE”

  switch,  the 

“NS-205PSE”

,  as  the  power  source.  The  NS-205PSE 

automatically detects any connected devices, whether they are PoE devices or not. This mechanism 

ensures that the NS-205PSE will function simultaneously with both PoE and non-PoE devices. 
 

Notes: 

1.

 

When acting as a power source for a PoE device, the NS-205PSE 

 

requires a power input ranging from +46 V

DC

 to +55 V

DC

.

 

2.

 

PoE (Power over Ethernet) means that the Ethernet cable conveys 
not only data but also power.

 

 

Step 1:

 Connect both the TouchPAD device and the Host PC to the same sub network or use a Power 

over Ethernet Switch (e.g., an NS-205PSE) and supply power to the TouchPAD device via the PoE 

Switch.   

 

 

 

Note

 that either “Ethernet” or “PoE” uses 

the same common Ethernet cable. 

Содержание TPD-280

Страница 1: ...nge this manual at any time without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use nor for any infringe...

Страница 2: ...4 7 VPD 130 130N 132 132N 133 133N 17 1 4 8 VPD 130 H 130N H 132 H 132N H 133 H 133N H 18 1 4 9 VPD 142 142N 143 143N 19 1 4 10 VPD 173N 173N 64 173X 173X 64 20 2 HARDWARE INFORMATION 21 2 1 APPEARANC...

Страница 3: ...3 Panel Mounting 60 2 4 4 XV boards Assembly on the VPD Series 62 3 GETTING STARTED 65 3 1 OBTAINING INSTALLING THE HMIWORKS SOFTWARE 65 3 2 CREATE A NEW PROJECT IN THE HMIWORKS 66 3 3 SUPPLY POWER T...

Страница 4: ...3 M2 TPD 283 M3 TPD 283U M1 TPD 283U M2 TPD 283U M3 TPD 430 H TPD 433 H TPD 433F H TPD 432F H TPD 433 M2 TPD 703 TPD 703 64 VPD Series Models VPD 130 VPD 130N VPD 132 VPD 132N VPD 133 VPD 133N VPD 142...

Страница 5: ...nique fashion and style Development is no longer difficult and project accomplishment is within reach ICP DAS provides two types of touch HMI devices the TPD series and the VPD series The TPD series i...

Страница 6: ...Tuner RS 232 3 pins RTC Real Time Clock Buzzer Rubber Keypad Option for VPD Series Graphical user interface designer Free development tool HMIWorks Support the C language and Ladder Designer Support u...

Страница 7: ...ach TPD VPD series product Touch Screen Size Communication Interface Special 28 2 8 inch 43 4 3 inch 70 7 0 inch For 2 8 inch 0 RS 485 0U RS 485 RTC 3 Ethernet 3U RS 485 RTC Ethernet For 4 3 inch 0 RS...

Страница 8: ...VDC or PoE TPD 280 Mx 4 1 x RS 485 12 48 VDC Yes TPD 283 Mx 4 Yes PoE Yes TPD 283U Mx 16 MB 108 Yes 1 x RS 485 Yes 12 48 VDC or PoE Yes 4 3 Resolution 480 x 272 Model Extra Flash Image Storage Capacit...

Страница 9: ...2 RS 485 Yes VPD 132N H VPD 133 H Yes Yes 12 48 VDC or PoE VPD 133N H Yes 4 3 Resolution 480 x 272 Model Extra Flash Image Storage Capacity Ethernet COM Port RTC Expansion I O Boards Rubber Keypad Ing...

Страница 10: ...Open Collector Sink Source XV107A 8 Sink Wet 8 Open Emitter Source XV110 16 Sink Source Wet Dry XV111 0 16 Open Collector Sink XV111A 0 16 Open Emitter Source XV116 5 Sink Source Wet 6 Power Relay Fo...

Страница 11: ...CPU 32 bit RISC CPU Memory Expansion 16 MB SDRAM 8 MB Flash 16 MB SDRAM 8 MB Flash Real Time Clock RTC Yes Yes Buzzer Yes Rotary Switch 0 9 Yes Communication Interface Ethernet RJ 45 x 1 10 100 Base...

Страница 12: ...Self Tuner USB 1 1 Client Firmware update only Firmware update only MMI Main Machine Interface LCD 2 8 TFT Resolution 240 x 320 65535 colors defective pixels 3 Backlight Life 20 000 hours Brightness 1...

Страница 13: ...65535 colors defective pixels 3 Backlight Life 20 000 hours Brightness 400 cd m2 Touch Panel Yes LED Indicator Yes Reset Button Yes Electrical Powered from Terminal Block 10 30 VDC Powered from PoE I...

Страница 14: ...defective pixels 3 Backlight Life 20 000 hours Brightness 400 cd m2 Touch Panel Yes LED Indicator Yes Reset Button Yes Electrical Powered from Terminal Block 12 48 VDC Powered from PoE IEEE 802 3af Cl...

Страница 15: ...S 485 including Self Tuner COM 2 RS 485 including Self Tuner RS 232 3 pin USB 1 1 Client Firmware update only MMI Main Machine Interface LCD 4 3 TFT Resolution 480 X 272 65535 colors defective pixels...

Страница 16: ...RS 232 3 pin non isolation MMI Main Machine Interface LCD 7 TFT Resolution 800 x 480 65535 colors defective pixels 3 Backlight Life 20 000 hours Brightness 250 cd m2 400 cd m2 Touch Panel 4 wire anal...

Страница 17: ...Self Tuner USB 1 1 Client Firmware update only I O Expansion I O Expansion Bus Yes One of XV boards MMI Main Machine Interface LCD 3 5 TFT Resolution 240 x 320 65535 colors defective pixels 3 Backligh...

Страница 18: ...lient Firmware update only I O Expansion I O Expansion Bus Yes One of XV boards MMI Main Machine Interface LCD 3 5 TFT Resolution 240 x 320 65535 colors defective pixels 3 Backlight Life 20 000 hours...

Страница 19: ...1 1 Client Firmware update only I O Expansion I O Expansion Bus Yes One of XV boards MMI Main Machine Interface LCD 4 3 TFT Resolution 480 x 272 65535 colors defective pixels 3 Backlight Life 20 000 h...

Страница 20: ...n or RS 485 including Self Tuner 2500 VDC isolated COM2 I O Expansion I O Expansion Bus Yes MMI Main Machine Interface LCD 7 TFT Resolution 800 x 480 65535 colors defective pixels 3 Backlight Life 20...

Страница 21: ...D 283U TPD 283 H and TPD 283U H 1 2 8 TFT LCD with Touch Panel 2 Power GND RS 485 Connector for TPD 280 280U 280 H 280U H 283U 283U H only The TouchPAD device is equipped with a removable terminal blo...

Страница 22: ...s a special run mode which is used in the development stage The TouchPAD device can be updated by a PC from the remote side through Ethernet 1 Ethernet Force Update While the application run on the To...

Страница 23: ...ve the top cover on the TouchPAD device 7 Reset Button Use a flat head screwdriver to press this button to reset the TouchPAD device Note The reset button does not behave as a reboot to the whole syst...

Страница 24: ...egarding the pin assignments refer to Section 2 2 1 TPD 280 283 430 433 Series Models 3 PoE and Ethernet RJ 45 Jack The TPD 280 Mx does not support this jack The TouchPAD device is equipped with an RJ...

Страница 25: ...ion to the TouchPAD device through Ethernet 2 Run Only Run the program For TPD 283U M1 M2 M3 0 Run Update Ethernet This is a special run mode which is used in the development stage The TouchPAD device...

Страница 26: ...e TouchPAD device is equipped with a removable terminal block connector is designed for easy and robust wiring For more detailed information regarding the pin assignments refer to Section 2 2 1 TPD 28...

Страница 27: ...This is a special run mode which is used in the development stage The TouchPAD device can be updated by a PC from the remote side through Ethernet 1 Ethernet Force Update While the application run on...

Страница 28: ...ler and this is not enough to make the program downloading successful Always cut the power then turn it on before downloading programs 5 PoE and Ethernet RJ 45 Jack for TPD 433F 433F H 433 M2 only The...

Страница 29: ...rnet This is a special run mode which is used in the development stage The TouchPAD device can be updated by a PC from the remote side through Ethernet 1 Ethernet Force Update While the application ru...

Страница 30: ...ice Note The reset button does not behave as a reboot to the whole system only resets the microcontroller and this is not enough to make the program downloading successful Always cut the power then tu...

Страница 31: ...an Ethernet link is detected and an Ethernet packet is received the Act LED Green indicator will be illuminated When power is supplied via PoE Power over Ethernet the PoE LED Orange indicator will be...

Страница 32: ...al block connector is designed for easy and robust wiring For more detailed information regarding the pin assignments refer to Section 2 2 5 VPD 130 Series Models 5 Rotary Switch 0 9 The Rotary Switch...

Страница 33: ...e Note The reset button does not behave as a reboot to the whole system only resets the microcontroller and this is not enough to make the program downloading successful Always cut the power then turn...

Страница 34: ...net link is detected and an Ethernet packet is received the Act LED Green indicator will be illuminated When power is supplied via PoE Power over Ethernet the PoE LED Orange indicator will be illumina...

Страница 35: ...uchPAD device seriously crashes use this mode to update a new application to the TouchPAD device through Ethernet 2 Run Only Run the program 9 USB Force Update Update a new application to the TouchPAD...

Страница 36: ...eset button does not behave as a reboot to the whole system only resets the microcontroller and this is not enough to make the program downloading successful Always cut the power then turn it on befor...

Страница 37: ...RS 485 Connector The TouchPAD device is equipped with a removable terminal block connector is designed for easy and robust wiring For more detailed information regarding the pin assignments refer to S...

Страница 38: ...terminal block connector is designed for easy and robust wiring For more detailed information regarding the pin assignments refer to Section 2 2 8 VPD 173N 173X Series Models 5 Ethernet RJ 45 Jack The...

Страница 39: ...opment stage The TouchPAD device can be updated by a PC from the remote side through Ethernet 1 Ethernet Force Update While the application run on the TouchPAD device seriously crashes use this mode t...

Страница 40: ...erial Port Data GND Ground Connection VDC DC Power Input The use as the power supply applies to TPD 280 283 430 433 Series models For TPD 280 280U 283U 430 430 EU 433 433 EU The valid power voltage ra...

Страница 41: ...ial Port D2 GND D1 2 wire RS 485 For COM 1 Serial Port D1 GND Ground Connection VDC DC Power Input The use as the power supply applies to TPD 432F The valid power voltage range is from 10 to 30 VDC Th...

Страница 42: ...erial Port TxD2 GND D1 2 wire RS 485 For COM 1 Serial Port D1 GND Ground Connection VDC DC Power Input The use as the power supply applies to TPD 433F The valid power voltage range is from 10 to 30 VD...

Страница 43: ...escription F G Frame Ground Frame Ground is connected to the inside EMI or ESD suppression circuits Make sure that F G is connected to the Earth P GND Ground Connection PWR DC Power Input The use as t...

Страница 44: ...n Name Function Description F G Frame Ground Frame Ground is connected to the inside EMI or ESD suppression circuits Make sure that F G is connected to the Earth VDC DC Power Input The use as the powe...

Страница 45: ...scription F G Frame Ground Frame Ground is connected to the inside EMI or ESD suppression circuits Make sure that F G is connected to the Earth VDC DC Power Input The use as the power supply applies t...

Страница 46: ...iption D2 2 wire RS 485 For COM2 Serial Port D2 GND 3 wire RS 232 RxD2 TxD2 D1 2 wire RS 485 For COM1 Serial Port D1 GND 3 wire RS 232 RxD1 TxD1 GND Ground Connection VDC DC Power Input The use as the...

Страница 47: ...R DC Power Input The use as the power supply applies to VPD 173N 173N 64 173X 173X 64 The valid power voltage range is from 12 to 48 VDC P GND Power Ground Connection F G Frame Ground Frame Ground is...

Страница 48: ...D Series HMI Device User Manual Copyright 2020 ICP DAS Co Ltd All Rights Reserved Page 48 2 3Dimensions 2 3 1 TPD 280 283 Series Models TPD 280 280U 280 H 280U H Units mm TPD 283 283U 283 H 283U H Uni...

Страница 49: ...TPD VPD Series HMI Device User Manual Copyright 2020 ICP DAS Co Ltd All Rights Reserved Page 49 TPD 280 Mx 283 Mx 283U Mx Units mm...

Страница 50: ...opyright 2020 ICP DAS Co Ltd All Rights Reserved Page 50 2 3 2 TPD 430 432 433 703 Series Models TPD 430 433 430 H 433 H Units mm TPD 430 EU 433 EU 430 H EU 433 H EU Units mm TPD 430 TPD 433 TPD 430 E...

Страница 51: ...TPD VPD Series HMI Device User Manual Copyright 2020 ICP DAS Co Ltd All Rights Reserved Page 51 TPD 432F 432F H Units mm TPD 433F 433F H Units mm TPD 433 M2 Units mm...

Страница 52: ...TPD VPD Series HMI Device User Manual Copyright 2020 ICP DAS Co Ltd All Rights Reserved Page 52 TPD 703 703 64 Units mm...

Страница 53: ...t 2020 ICP DAS Co Ltd All Rights Reserved Page 53 2 3 3 VPD 130 132 133 Series Models VPD 130 130N 130 H 130N H Units mm VPD 132 132N 132 H 132N H 133 133N 133 H 133N H Units mm VPD 132 H 133 H VPD 13...

Страница 54: ...nual Copyright 2020 ICP DAS Co Ltd All Rights Reserved Page 54 2 3 4 VPD 142 143 173N 173X Series Models VPD 142 143 142 H 143 H Units mm VPD 142N 143N 142N H 143N H Units mm VPD 142 142 H VPD 143 143...

Страница 55: ...TPD VPD Series HMI Device User Manual Copyright 2020 ICP DAS Co Ltd All Rights Reserved Page 55 VPD 173N 173N 64 173X 173X 64 Units mm VPD 173N 173N 64 VPD 173X 173X 64...

Страница 56: ...td All Rights Reserved Page 56 2 4Mounting the Hardware 2 4 1 Wall Mounting For TPD 280 280U 280 H 280U H 283 TPD 283U 283 H 283U H 2 8 EWB T28 BK EWB T28 External Wall Box For TPD 430 EU 433 EU 430 H...

Страница 57: ...right 2020 ICP DAS Co Ltd All Rights Reserved Page 57 For TPD 430 433 430 H 433 H 4 3 EWB T43 BK EWB T43 External Wall Box Outlet Box OB120 For TPD 432F 433F 432F H 433F H 4 3 External Wall Box EWB T4...

Страница 58: ...ice User Manual Copyright 2020 ICP DAS Co Ltd All Rights Reserved Page 58 For TPD 433 M2 4 3 External Wall Box EWB T43F2 Outlet Box OB140F For TPD 703 703 64 7 External Wall Box EWB T70 Outlet Box OB1...

Страница 59: ...VPD Series device can be mounted by attaching the bottom of the chassis to a DIN Rail or the wall The DIN Rail mounts are available in three size and enable a variety of ICP DAS devices to be mounted...

Страница 60: ...ximum thickness 5 mm Adequate access space can be available at the rear of the instrument panel for wiring and servicing purposes 1 Prepare the panel and cut the hole to the specified size The detaile...

Страница 61: ...the panel mounting clips into the upper and lower ventilation holes 4 Screw the panel mounting clips to the panel VPD 130 132 133 142 143 Series VPD 173N 173X Series Mounting Screw M4 x 30L Note Reco...

Страница 62: ...User Manual Copyright 2020 ICP DAS Co Ltd All Rights Reserved Page 62 2 4 4 XV boards Assembly on the VPD Series 2 4 4 1 VPD 132 133 142 143 Series What s in the package Follow the procedure described...

Страница 63: ...TPD VPD Series HMI Device User Manual Copyright 2020 ICP DAS Co Ltd All Rights Reserved Page 63 7 8 9 10...

Страница 64: ...TPD VPD Series HMI Device User Manual Copyright 2020 ICP DAS Co Ltd All Rights Reserved Page 64 2 4 4 1 VPD 173X Series What s in the package 1 2 3 5 6 7 4 8...

Страница 65: ...re on your PC HMIWorks is the development tools for the TouchPAD devices The HMIWorks can be obtained from the ICP DAS FTP site or the web site The location of the download addresses are shown below h...

Страница 66: ...e a new project Step 3 In the New dialog box configure the parameters for the new project as follows 1 Click the name of the TouchPAD model to select it e g TPD 433 H 2 Enter a name for the project e...

Страница 67: ...xample creates a simple procedure that displays the string Hello TouchPAD on the screen of the TouchPAD device 1 Click the Text icon from the Toolbox pane 2 Drag and click the Text tag to the desired...

Страница 68: ...on in the Font field from the Inspector pane to setting the text size style color etc 5 The creation of the string Hello TouchPAD sample is now complete it can be uploaded to the TouchPAD device refer...

Страница 69: ...VDC pin on the TouchPAD device The valid power voltage range depends on the type of TPD VPD Series device Please refer to the table below Model TPD TPD 280 280U 283U TPD 430 430 EU TPD 433 433 EU TPD...

Страница 70: ...y are PoE devices or not This mechanism ensures that the NS 205PSE will function simultaneously with both PoE and non PoE devices Notes 1 When acting as a power source for a PoE device the NS 205PSE r...

Страница 71: ...ownloaded Devices The following models use RS 485 to download the HMIWorks built applications TPD 280 TPD 280 H TPD 280 M1 M2 M3 3 4 1 1 Applications are downloaded through RS 485 The following flow c...

Страница 72: ...y Power to the TouchPAD for more details Step 2 Connect the TouchPAD device to the Host PC through a RS 485 converter For example I 7520 RS 232 to RS 485 converter or I 7561 USB to RS 485 converter St...

Страница 73: ...Set up Device TouchPAD item from the Run menu to open Setup Serial Device dialog box Step 5 In the Setup Serial Device dialog box select the COM Port e g COM7 depending on your PC COM Port that connec...

Страница 74: ...OK button to continue Step 8 The Download in progress dialog box will be displayed showing the progress of the update Step 9 Once the upload is complete i e when the progress indicator reaches 100 po...

Страница 75: ...2 What to do if the download process hangs Anytime download process hangs users can follow the flow below to complete the download process Reboot the TouchPAD Start Set Rotary Switch 1 Update Only Do...

Страница 76: ...64 3 4 2 1 Applications are downloaded through Ethernet The following flow chart describes the Ethernet downloading procedures 1 Design user interface and program on HMIWorks 2 Rotary Switch set to 0...

Страница 77: ...ownload program may not work Please contact with your system Administrator Step 1 Use a flat head screwdriver to set the Rotary Switch on the TouchPAD device to position 0 Run Update mode and power re...

Страница 78: ...evice dialog box click the Search for TouchPAD button to open Search for TouchPAD dialog box Step 5 If the TouchPAD device is found and displayed in the list on the Search for TouchPAD dialog box sele...

Страница 79: ...as a part of the program image DHCP The IP address of the TouchPAD is dynamically allocated from a DHCP server Please ensure that there is a DHCP server in the environment Runtime Setting TouchPAD loa...

Страница 80: ...our TouchPAD device and click the OK button Note Verify that the new project has been created see Section 3 2 Create a New Project in the HMIWorks Step 9 Click the Run Render Compile Download F9 item...

Страница 81: ...l Copyright 2020 ICP DAS Co Ltd All Rights Reserved Page 81 Step 10 The Download in progress dialog box will be displayed showing the progress of the update Step 12 The TouchPAD device will then execu...

Страница 82: ...llow the flow below to complete the download process YES 1 Set Rotary Switch 1 2 Reboot the TouchPAD and start download again Start Download Process Hangs Set Rotary Switch 0 Reboot the TouchPAD END N...

Страница 83: ...TPD 433F 433F H 433 M2 VPD 130 130N 130 H 130N H VPD 132 132N 132 H 132N H VPD 133 133N 133 H 133N H VPD 142 142N 142 H 142N H VPD 143 143N 143 H 143N H VPD 173X 173X 64 3 4 3 1 Applications are downl...

Страница 84: ...y to the TouchPAD device Refer to Section 3 3 Supply Power to the TouchPAD for more details Step 2 Connect the TouchPAD device to the Host PC using a CA USB10 cable Step 3 Power off the TouchPAD devic...

Страница 85: ...t the new project has been created see Section 3 2 Create a New Project in the HMIWorks Step 5 In the HMIWorks software click the Run Render Compile Download F9 item from the Run menu or press F9 key...

Страница 86: ...e the upload is complete i e when the progress indicator reaches 100 power off the TouchPAD device and set the Rotary Switch to position 0 Run mode Step 8 Power on and reboot TouchPAD device so that t...

Страница 87: ...8 on them but still some do have Each version of HMIWorks corresponds to a version of MiniOS8 Though we try to achieve backward compatibility we still suggest update MiniOS8 every time HMIWorks is upd...

Страница 88: ...on the TouchPAD device to position 1 Update OS mode and power off then power on the TouchPAD Note that the default configuration is position 0 Step 4 Connect the TouchPAD device to the Host PC using a...

Страница 89: ...continue Step 7 The Download in progress dialog box will be displayed showing the progress of the update Step 8 Once the upload is complete i e when the progress indicator reaches 100 a configuration...

Страница 90: ...to do if the download process hangs Anytime download process hangs users can follow the flow below to complete the download process Power off then power on the TouchPAD Start Set Rotary Switch 9 Upda...

Страница 91: ...eens we introduce the flow below You can find that the calibration programs are in the following directory HMIWorks_Install_Path bin boot Device_Name calibrate For example there are two calibration pr...

Страница 92: ...20 ICP DAS Co Ltd All Rights Reserved Page 92 Refer Readme txt to execute calibration when contains a Readme txt file in the calibrate folder Double click calibrate bat file to execute calibration whe...

Страница 93: ...e Device Using a PET 7060 module Ethernet I O Module with 6 channel Relay output 6 channel Digital Input as an example ensure that the network settings for both the Modbus TCP slave device and the Hos...

Страница 94: ...Ltd All Rights Reserved Page 94 Step 2 Select Modbus TCP Master from the TouchPAD is drop down menu Step 3 Select PET 7000 from the Device Series drop down menu Step 4 Select Create New from the Conne...

Страница 95: ...n the Connection Name field 2 Select TCPIP from the Connection Interface drop down menu 3 Enter the IP Address of the PET 7060 module in the IP Address field 4 Enter the TCP Port of the PET 7060 modul...

Страница 96: ...n click the OK button to save the configuration and close the Devices dialog box For more detailed information regarding the Self test process which is used to confirm that the PET 7060 and TouchPAD a...

Страница 97: ...nect the Modbus RTU slave device to the TouchPAD model on RS 485 COM Port and apply power to the Modbus RTU slave device and TouchPAD model The following will access to connect to Modbus RTU slave dev...

Страница 98: ...dialog box configure the connection information of the M 7060 module in the following manner 1 Enter a name for the connection e g SER_1 in the Connection Name field 2 Select COM1 from the Connection...

Страница 99: ...al Copyright 2020 ICP DAS Co Ltd All Rights Reserved Page 99 Step 6 Click the Select button to open the Select M 7000 Series dialog box Step 7 In the Select M 7000 Series dialog box select the M 7060...

Страница 100: ...hen click the OK button to save the configuration and close the Devices dialog box For more detailed information regarding the Self test process which is used to confirm that the M 7060 and TouchPAD a...

Страница 101: ...Value Net ID 1 Baud Rate 115200 Comport XVBus Communication Interface Modbus RTU XV Board as slave Using C Programming Language to Control XV board XV Board HANDLE h int NetID 1 int addr 1 int ch_cou...

Страница 102: ...e 102 Using Ladder Designer Step 1 In the HMIWorks software click the Register Devices I O option from the HMI menu to open the Devices dialog box or press F3 key Step 2 Select Modbus RTU Master from...

Страница 103: ...n the New Edit Connection dialog box Step 5 In the New Edit Connection dialog box configure the connection information of the XVBoard in the following manner 1 Enter a name for the connection e g XVBu...

Страница 104: ...XVBoard Series dialog box Step 7 In the Select XVBoard Series dialog box select the model and then click the OK button Step 8 Verify that the information for XV Board is correct e g the Device Name N...

Страница 105: ...with TouchPAD which location of the download addresses are shown below https www icpdas com en download show php num 1000 root model kw HMIWorks For more detailed information regarding how to use Tou...

Страница 106: ...t the VPD 173N 173N 64 and TPD 433F H specification in Section 1 4 Specifications 2 Added the information about the VPD 173N 173N 64 and TPD 433F H appearance in Section 2 1 Appearance 3 Added the inf...

Страница 107: ...PD 433 H 433F H 433 M2 and VPD 133 H 143 H models in the Section 3 4 2 Setup Ethernet downloaded Devices 2 Added the TPD 283U H 283U Mx in the Section 3 4 3 Setup USB downloaded Devices 1 4 Apr 2018 1...

Отзывы: