It provides three types of status indicator, they are PWR 
LED (yellow), ERR LED (red) and RUN LED (green). 
When the power is supplied to module, PWR LED will 
turn on; If CHK_CFG procedure is finished, RUN LED will 
turn on and ERR LED will turn off. The table explains the 
relationship between them. 

 

Status Indicator 

Meaning 

Recommend solution 

ERR ON & 

Offline Mode 

Check the address setting of 

RUN OFF 

module and DP-master. 

 

ERR Flash(0.1 sec)  Stop Mode 

Check the DP-Master is ready 
to communicate with module. 

 

 

 

 

 

 

 

Check the setting of module in 

ERR Flash(0.5 sec)  Prm Fault 

the master interface and make 

 

 

sure of the consistency. 

ERR Flash(1 sec) 

Cfg Fault 

Same as above 

 

 

 

ERR  ON  &  RUN 

Clear Mode 

Sets the DP-Master from clear 

ON 

 

mode to operation mode 

ERR OFF & 

Operate Mode 

 

RUN ON 

 

 

 

 

 

 

PWR & 

Diag Exist 

Check the Input/Output value 

ERR Flash 

(Diag. Msg. 

that if exceed/under the limit 

lnterlace(0.5 sec) 

Request) 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание PROFI-5045

Страница 1: ...Meaning 3 B Line Receive Transmit data plus 5 GND Power ground of active terminator 6 VP Power 5 volt of active terminator 8 A Line Receive Transmit data minus The PROFIBUS connector is a standard 9 p...

Страница 2: ...n and ERR LED will turn off The table explains the relationship between them Status Indicator Meaning Recommend solution ERR ON Offline Mode Check the address setting of RUN OFF module and DP master E...

Страница 3: ...diagram The PROFI 5000 doesn t have any terminating resistors inside Therefore users must add the terminator in external In general PROFIBUS connector has terminating resistors inside and there is a...

Страница 4: ...d the other one is low nibble of address Module applies the setting of rotary switch as its address if the address is valid While the address is invalid module loads the pre saved value from EEPROM Mo...

Страница 5: ...ita CA 90717 5 PROFI 5000 Setting and Module installation example for SIMATIC Step 7 The following steps can help users to set and apply the PROFI 5000 1 Address Setting 2 Load GSD file into the DP Ma...

Страница 6: ...DAQ Module QuickStart Apr 2017 ICP DAS USA Inc www icpdas usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 6 d Install OK 3 Select I O modules a Choose PROFI 5000 b add I O module t...

Страница 7: ...e 200 Lomita CA 90717 7 c Modify system parameters and module parameters modify by user s preference System parameters Double click PROFI 5000 Module parameters Double click module 4 Download Setting...

Страница 8: ...as usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 8 b Select PLC Download After the procedure finish DP Master will establish the connection with PROFI 5000 and execute program au...

Страница 9: ...PROFI 5053 PROFIBUS DAQ Module QuickStart Apr 2017 ICP DAS USA Inc www icpdas usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 9 PROFI 5000 Quick Start Version 2 1 June 2013 8...

Отзывы: