background image

 

 

PROFI-5053  PROFIBUS DAQ Module - QuickStart (Apr/2017)  

ICP DAS USA, Inc.

 | 

www.icpdas-usa.com

 | 1-310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717

 

 

- The figure shown above is the decimal rotary switch. It dominates 

the node (station) address of PROFI-5000. The left side switch is 
high nibble of address and the other one is low nibble of address. 

 

- It doesn’t support SSA service for setting node address. 

 

EX 1 : MSB = 2, LSB = 3, node address => (2*10+3) = 23 

 

 

PROFI-5017/ PROFI-5017C/ PROFI-5018/ PROFI-5024 

 
 
 
 
 
 
 
 

-  The figure shown above is the decimal rotary switch. It dominates 

the node (station) address of PROFI-5000. The switch is which 
labeled MSB is high nibble of address and the other one is low 
nibble of address. 

-  Module applies the setting of rotary switch as its address if the 

address is valid. While the address is invalid, module loads the pre-
saved value from EEPROM. Moreover, if the address is invalid 
(126) again, module awaits the SSA telegram and applies it. (Note: 
If you want to clear the setting stored at EEPROM, you just adjust 
rotary switch to FF before the power supplied). 

 

Rotary 

Pre-saved address  SSA Telegram 

PROFI-5017(C) 

Switch(dec) 

(EEPROM) 

 

Station Address 

0~125 

Do not care 

No Accept 

Rotary Switch 

126~254 

0~125 

No Accept 

Pre-saved 

 

 

 

address(EEPROM) 

 

 

 

 

 

126(default) 

Accept with 

SSA Telegram and 

 

 

address 0~125 

save address to 

 

 

 

EEPROM 

 

 

 

 

 

127~254 

impossible 

N/A 

 

 

 

 

255 

Clear to 126 

Accept with 

SSA telegram and 

 

 

address 0~125 

save address to 

 

 

 

EEPROM 

 

EX 1 : MSB = 0, LSB = B, node address => (0*16+11) = 11 

 

EX 2 : MSB =7, LSB = 9, node address => (7*16+9) = 121 

 
 
 

Содержание PROFI-5045

Страница 1: ...Meaning 3 B Line Receive Transmit data plus 5 GND Power ground of active terminator 6 VP Power 5 volt of active terminator 8 A Line Receive Transmit data minus The PROFIBUS connector is a standard 9 p...

Страница 2: ...n and ERR LED will turn off The table explains the relationship between them Status Indicator Meaning Recommend solution ERR ON Offline Mode Check the address setting of RUN OFF module and DP master E...

Страница 3: ...diagram The PROFI 5000 doesn t have any terminating resistors inside Therefore users must add the terminator in external In general PROFIBUS connector has terminating resistors inside and there is a...

Страница 4: ...d the other one is low nibble of address Module applies the setting of rotary switch as its address if the address is valid While the address is invalid module loads the pre saved value from EEPROM Mo...

Страница 5: ...ita CA 90717 5 PROFI 5000 Setting and Module installation example for SIMATIC Step 7 The following steps can help users to set and apply the PROFI 5000 1 Address Setting 2 Load GSD file into the DP Ma...

Страница 6: ...DAQ Module QuickStart Apr 2017 ICP DAS USA Inc www icpdas usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 6 d Install OK 3 Select I O modules a Choose PROFI 5000 b add I O module t...

Страница 7: ...e 200 Lomita CA 90717 7 c Modify system parameters and module parameters modify by user s preference System parameters Double click PROFI 5000 Module parameters Double click module 4 Download Setting...

Страница 8: ...as usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 8 b Select PLC Download After the procedure finish DP Master will establish the connection with PROFI 5000 and execute program au...

Страница 9: ...PROFI 5053 PROFIBUS DAQ Module QuickStart Apr 2017 ICP DAS USA Inc www icpdas usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 9 PROFI 5000 Quick Start Version 2 1 June 2013 8...

Отзывы: