background image

P6 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

Model Name 

Type and Rating 

Size A  Size B 

iWSN-9601-PCT-ME-IP33 

Split CT, Max. 400 A 

iWSN-9601-160-ME-IP33 

Split CT, 100 A 

15.7 

29 

iWSN-9601-240-ME-IP33 

Split CT, 200 A 

23.6 

45.2 

iWSN-9601-360-ME-IP33 

Split CT, 400 A 

35.7 

57.5 

 

6. 

Module Installation 

 

7. 

Operations

 

Users can prepare a PC and iWSN-200U (or iWSN-200E) for data collection 

of iWSN-9601 series modules. 

1.

 

Configure  the  RF  channel  and  Group  ID  of  iWSN-200U/E  to  the  same 
configuration of the iWSN-9601 series modules.   

2.

 

Set

 

the  Node  ID  (1  ~  31), 

wiring type and Tx duty, and 
finish the wiring connection. 
The  Node  ID  must  be 
unique  in  a  sub-network 
(the  same  RF  channel  and 
group  ID).  The  architecture 
might  look  like  as  the 
right-hand-side figure. 

        The  iWSN-9601  series  provide  the 
IP33 rating enclosure which can effectively 
prevent the modules from the influence of 
the  fire  sprinkler  systems.  Users  need  to 
install the module vertically and screws up 
the  LED  panel  cover  and  connector 
protector  properly  to  guarantee  the  IP33 
rating performance. 

 

The  iWSN-9601  series  modules  can  only  be  used 
with  the  specific  CTs.  Only  the  model  name 
iWSN-9601-PCT-ME-IP33  doesn’t  include  CTs. 
Please  check  the  accessories  of  the  product 
website  or  contact  to  the  ICP  DAS  distributor  to 
purchase  the  CTs  for  this  model  if  necessary. 
Different  model  name  provides  different  size  of 
CTs, they are described below.

 

Unit: mm

 

Vertical 

Horizontal 

Содержание iWSN-9601 Series

Страница 1: ...ries Screw driver Split Core CT 4 M4 16L Mounting Screws Model Name Split Core CTs iWSN 9601 ME IP33 160 240 360 6 iWSN 9601 PCP ME IP33 None Technical Support service icpdas com www icpdas com Resour...

Страница 2: ...Error status indicator Err Yellow LED Actions Descriptions Red LED is always OFF No power Red LED is always ON Working power is given Both Green and Yellow LEDs are ON Module is initializing Both Gree...

Страница 3: ...RF group ID and the PA function 3 Trigger button for forcing to transmit data once Holding it 5 seconds will reset the module The Configurations and descriptions of L Switch and R Switch are as follow...

Страница 4: ...scriptions Node ID NID Up Down NID Pin NID Pin 1 2 3 4 5 1 2 3 4 5 0 16 1 17 2 18 3 19 4 20 5 21 6 22 7 23 8 24 9 25 10 26 11 27 12 28 13 29 14 30 15 31 Group ID Up Down RF Group ID Pin 6 7 0 1 2 3 PA...

Страница 5: ...terminal labeled B is for connection to the CT black wire AC voltage input connector AC and AC are connected to the L phase and N phase of the single phase power supply Normally GND must be shorted t...

Страница 6: ...a sub network the same RF channel and group ID The architecture might look like as the right hand side figure The iWSN 9601 series provide the IP33 rating enclosure which can effectively prevent the m...

Страница 7: ...N 9601 360 ME IP33 EMS Protection EFT IEC 61000 4 4 500 V ESD IEC 61000 4 2 4 kV Contact LED Indicators Status 1 for Power 1 for Tx and 1 for Error AC Power Measurement Wiring 1P2W 1CT Loops 6 Input V...

Страница 8: ...0 3 Radio Frequency 433 1000 434 6000 MHz Transmission Power 9 1 dBm Typical Transmission Distance LoS 100 m Node ID 1 31 Working Duty 1 10 30 or 60 seconds Mechanical Dimensions mm 85 x 184 x 47 W x...

Страница 9: ...his manual at any time without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use not for any infringements...