7.4. CAN Error Counter Register
Bit
Symbol Value
Description
7:0
TEC
Transmit error counter
Current value of the transmit error counter (maximum value 255)
14:8
REC
Receive error counter
Current value of the receive error counter (maximum value 127).
15
RP
Receive error passive
0
The receive counter is below the error passive level.
1
The receive counter has reached the error passive level as defined
in the CAN2.0 specification.
31:16
-
-
Reserved