background image

 

I-7565 USB/CAN Converter Quick Start User Guide (Version 1.0, March/2007)  ------ 3

 

3.   The I-7565 Parameters Configuration 

Before starting the I-7565 converter tests, users need to configure the 

USB & CAN parameters via the I-7565 Utility tool. The details of this 
procedure are shown below. 

 

Step1: Set the Init/Normal switches on the back of the I-7565 A to the 

“Init” position. Then, connect to the USB port of PC.  The ON LED 
of the I-7565 A will be flash approximately once per second.  That 
means that the I-7565 is in the configuration mode. 

Step2: Run the I-7565 Utility. The “I7565.exe” is located in the 

can_cd\can\converter\i-7565\ folder on the companion CD-ROM or 
can be downloaded from the web site:  

 

http://ftp.icpdas.com/pub/cd/can_cd/can/converter/i-7565/utility/

 
Step3: Click the “Connect” icon to select the USB port and Baud rate, 

which are used to connect with the I-7565 A. The steps are shown 
in the following figure. 

 

 

 

 

 
 

Отзывы: