I-7565 USB/CAN Converter Quick Start User Guide (Version 1.0, March/2007) ------ 2
2. Hardware Installation
Users need to make a hardware connection between the CAN
devices before the application. The details of this are illustrated below:
Step1: Set-up the 120
Ω
terminator resistor of module A and B.
Before you continue, if you have changed the settings from default
then it is necessary to open the cover for each I-7565 and re-configure
their JP3 jumpers to enable them again, as shown in below figure.
However if the I-7565’s still have their default settings then it is not
necessary to open and reset them because the default configuration is
enabled.
Enable (default),
(Activate)
Step2: USB connection
Connect the USB ports of the I-7565 A and I-7565 B to the USB on
the PC respectively.
Step4: CAN bus connection
Connect the CAN ports of these two I-7565 modules by using the
following structure.