I-7530A RS-232/485/422 to CAN Converter User’s Manual (Version 1.2, Sep/2011) ------------- 28
4.1 tIIILDD…[CHK]<CR>
Description:
Send or receive a standard CAN data frame.
¾
Syntax: tIIILDD…[CHK]<CR>
t
Represent a standard (2.0A) data frame.
III
11 bits Identifier (0x000~0x7FF)
L
Data length of a CAN message (0x0~0x8)
DD…
Input data frame value according to the data length
(0x00~0xFF)
¾
Response:
Valid command: No response
Invalid command: ?<Error Code><CR>
¾
Note:
It is necessary to enable the “Error Response” function in the I-
7530 Utility, in order to receive Syntax and/or communication error
information at the host PC.
¾
Example:
Command: t03F6112233445566<CR>
Send a CAN message with a standard data frame. ID=0x03F,
DLC=0x6, data1=0x11, data2=0x22, data3=0x33, data4=0x44,
data5=0x55 and data6=0x66.