P8 

3.4  Click the "Run the CAN Port" button and the operation window 

will be popped up. 

 

 

 

The operation window is divided to two areas. One is for sending 
CAN  messages,  and  the  other  is  for  reception.  If  users  want  to 
send CAN message, fill the data into the corresponding field, and 

click “Send” button

. If the I-7530 gets any CAN messages, 

they will be shown in received area automatically. 
 
About the details for the VxCAN Utility operation, please refer to 
the Users’ manual of the VxCAN Utility in the following link: 
https://www.icpdas.com/web/product/download/software/utilit
y_driver/vxcan/document/manual/VxCAN_Utility_Manual_en.pd
f

 

 
 

Содержание I-7530

Страница 1: ...o this guide the package includes the following items I 7530 CA 0915 Plastic Rail Technical Support service icpdas com www icpdas com Resources How to search for drivers manuals and spec information o...

Страница 2: ...s or only have one terminator resistor on the CAN bus the CAN network may be malfunction If users would like to enable or disable the terminator resistor inside the I 7530 it is necessary to open the...

Страница 3: ...ent and uses the D sub 9 pins female connector for the RS 232 interface The following figure describes the wire connection between the PC and the I 7530 1 4 CAN bus connection The CAN port of I 7530 u...

Страница 4: ...that the I 7530 is in the configuration mode 2 2 Connect the available COM port of the PC to the I 7530 and execute the VxCAN Utility VxCAN Utility can be downloaded from the following link https www...

Страница 5: ...xCAN Utility 2 5 Click the I 7530 Init in the list the configuration window will be popped up The configuration window is divided to three areas with different color They are UART CAN and Communicatio...

Страница 6: ...he default values of the parameters of the I 7530 are shown below UART Baud rate 115200 bps Data Bit 8 Stop Bit 1 Parity None Add Checksum No Error Response No CAN CAN Specification 2 0A CAN Bus Baud...

Страница 7: ...ndow of VxCAN Utility 3 3 Click the CAN port of the I 7530 to set the CAN parameters of the I 7530 Check the Active Port and Click Confirm button to enable the CAN port of the I 7530 The CAN parameter...

Страница 8: ...end CAN message fill the data into the corresponding field and click Send button If the I 7530 gets any CAN messages they will be shown in received area automatically About the details for the VxCAN U...