I-7530 RS-232/CAN Converter User’s Manual (Version 2.5, Mar/2012) ------------- 33
Table 9: RS-232 baud rate list
BB Description
00
110 bps baud rate of RS-232
01
150 bps baud rate of RS-232
02
300 bps baud rate of RS-232
03
600 bps baud rate of RS-232
04
1200 bps baud rate of RS-232
05
2400 bps baud rate of RS-232
06
4800 bps baud rate of RS-232
07
9600 bps baud rate of RS-232
08
19200 bps baud rate of RS-232
09
38400 bps baud rate of RS-232
0A
57600 bps baud rate of RS-232
0B
115200 bps baud rate of RS-232
¾
Response:
A valid command will write the RS-232 configuration
parameters into the EEPROM and then reboot the I-7530 module.
Invalid command: ?<Error Code><CR>
¾
Note:
It is necessary to enable the “Error Response” function in the I-
7530 Utility, in order to receive Syntax and/or communication error
information at the host PC.
¾
Example:
Command: P00B30000<CR>
Set the RS232 baud rate=115.2K, data bit=8, stop bit=1, none parity,
no checksum and No error responses into the I-7530 module and
then reboot the I-7530 module.