I-7530 RS-232/CAN Converter User’s Manual (Version 2.5, Mar/2012) ------------- 30
¾
Response:
Valid command: No response
Invalid command: ?<Error Code><CR>
¾
Note:
It is necessary to enable the “Error Response” function in the I-
7530 Utility, in order to receive Syntax and/or communication error
information at the host PC.
¾
Example:
Command: E010156786<CR>
Send a CAN message with an extended remote frame. ID=01015678,
DLC=6.
4.5 S[CHK]<CR>
Description:
Read the I-7530 CAN Baud Rate and error flag message.
¾
Syntax: S[CHK]<CR>
S
Command character.
¾
Response:
Valid Command: !CFFTTRRO[CHK]<CR>
Invalid command: ?<Error Code>[CHK]<CR>
!
Delimiter for valid command
C
current baud rate setting of CAN
FF
CAN register
TT
CAN transmit error counter
RR
CAN receive error counter
O
CAN/RS-232 FIFO Overflow flag
¾
Note
:
It is necessary to enable the “Error Response” function in the I-
7530 Utility, in order to receive Syntax and/or communication error
information at the host PC. Furthermore, all response results are
shown in the ASCII format. Users need to make an ASCII to hex
format transformation in order to understand what the meaning is
based on the following table.