I-2533T-FD ( CAN/CAN FD to Multi-mode Fiber Bridge ) User Manual (version 1.0.0)     

Page: 44

 

 

Copyright © 2021 ICP DAS Co., Ltd. All Rights Reserved. E-mail: [email protected]

 

6.5.  Valid CAN FD Data Phase Bit Rat 

 

 

Supported CAN FD Data Phase Bit Rate (kbps) 

Items

 

10000.000 

8571.429 

7500.000 

6666.667 

6000.000 

5454.545 

5000.000 

4615.385 

4285.714 

4000.000 

10 

3750.000 

3529.412 

3333.333 

3157.895 

3000.000 

15 

2857.143 

2727.273 

2608.696 

2500.000 

2400.000 

20 

2307.692 

2222.222 

2142.857 

2068.966 

2000.000 

25 

1935.484 

1875.000 

1818.182 

1764.706 

1714.286 

30 

1666.667 

1621.622 

1578.947 

1538.462 

1500.000 

35 

1463.415 

1428.571 

1395.349 

1363.636 

1333.333 

40 

1304.348 

1276.596 

1250.000 

1224.49 

1200.000 

45 

1176.471 

1153.846 

1132.075 

1111.111 

1090.909 

50 

1071.429 

1052.632 

1034.483 

1016.949 

1000.000 

55 

983.6066 

967.7419 

952.381 

937.500 

923.0769 

60 

909.0909 

895.5224 

882.3529 

869.5652 

857.1429 

65 

845.0704 

833.3333 

821.9178 

810.8108 

800.000 

70 

789.4737 

779.2208 

769.2308 

759.4937 

750.000 

75 

740.7407 

731.7073 

722.8916 

714.2857 

705.8824 

80 

697.6744 

689.6552 

681.8182 

674.1573 

666.6667 

85 

659.3407 

652.1739 

645.1613 

638.2979 

631.5789 

90 

625.000 

618.5567 

612.2449 

606.0606 

600.000 

95 

594.0594 

588.2353 

582.5243 

576.9231 

571.4286 

100 

566.0377 

560.7477 

555.5556 

550.4587 

545.4545 

105 

540.5405 

535.7143 

530.9735 

526.3158 

521.7391 

110 

517.2414 

512.8205 

508.4746 

504.2017 

500.000 

115 

495.8678 

491.8033 

487.8049 

483.871 

480.000 

120 

476.1905 

472.4409 

468.750 

465.1163 

461.5385 

125 

458.0153 

454.5455 

451.1278 

447.7612 

444.4444 

130 

441.1765 

437.9562 

434.7826 

431.6547 

428.5714 

135 

425.5319 

422.5352 

419.5804 

416.6667 

413.7931 

140 

410.9589 

408.1633 

405.4054 

402.6846 

400.000 

145 

397.351 

394.7368 

392.1569 

389.6104 

387.0968 

150 

384.6154 

382.1656 

379.7468 

377.3585 

375.000 

155 

372.6708 

370.3704 

368.0982 

365.8537 

363.6364 

160 

361.4458 

359.2814 

357.1429 

355.0296 

352.9412 

165 

350.8772 

348.8372 

346.8208 

344.8276 

342.8571 

Содержание I-2533T-FD

Страница 1: ...Multi mode Fiber Bridge User Manual version 1 0 0 Page 1 Copyright 2021 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com I 2533T FD User Manual Version 1 0 0 April 2021 Service and usage i...

Страница 2: ...s product ICP DAS reserves the right to change this manual at any time without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed...

Страница 3: ...istor Setup 17 2 7 Module Group ID 19 2 8 Wire Connection 21 3 Network Deployment 22 3 1 Driving Capability 22 3 2 Fiber Selection Fiber Length 23 4 Software Utility 24 4 1 Install the I 2533CS FD Uti...

Страница 4: ...CAN FD to Multi mode Fiber Bridge User Manual version 1 0 0 Page 4 Copyright 2021 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 6 4 CAN Error Counter Register 43 6 5 Valid CAN FD Data P...

Страница 5: ...ns that the total CAN CAN FD bus working distance can be extended Second the bus error on one CAN CAN FD network will not affect the operation of another CAN CAN FD network Finally the two CAN CAN FD...

Страница 6: ...I 2533T FD CAN CAN FD to Multi mode Fiber Bridge User Manual version 1 0 0 Page 6 Copyright 2021 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com...

Страница 7: ...he 120 terminal resistor Isolation 3000 VDC for DC to DC 2500 Vrms for photocoupler Specification ISO 11898 2 CAN 2 0 A B and FD CAN Filter Configuration Selectable via Utility tool Receive Buffer 128...

Страница 8: ...D PWR FB_Ack FB_Err CAN_Err CAN_Tx and CAN_Rx LEDs Power Power supply Unregulated 10 30 VDC Protection Power reverse polarity protection Over voltage brown out protection Power Consumption 0 125A 24VD...

Страница 9: ...2 0 A B and FD CAN FD support for ISO and Non ISO Bosch standards switchable CAN FD bit rates for data field from 100 kbps to 10000 kbps CAN bit rates from 10 kbps to 1000 kbps Fiber broken line detec...

Страница 10: ...version 1 0 0 Page 10 Copyright 2021 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 2 Technical data 2 1 Block Diagram The following figure is the block diagram illustrating the function...

Страница 11: ...T FD CAN CAN FD to Multi mode Fiber Bridge User Manual version 1 0 0 Page 11 Copyright 2021 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 2 2 Appearance Figure 2 2 1 Appearance of I 253...

Страница 12: ...ort and power connector of I 2533T FD is shown in the following tables Table 2 3 1 Pin Assignment Port Name Description USB USB Used for configuration utility CAN CAN_L CAN_Low signal line of CAN port...

Страница 13: ...ation users can connect the CAN_GND of different CAN devices with each other to balance the voltage level of CAN_GND Electronic circuits are always influenced by different levels of Electro Static Dis...

Страница 14: ...vice icpdas com 2 4 10 pin Dip Switch When users would like to set the CAN CAN FD baud rate module s group id or update the firmware of the I 2533T FD Users can use the 10 pin dip switch on the upper...

Страница 15: ...Function Description ON OFF 1 3 Arbitration Bit Rate of CAN CAN FD message Bit Rate kbps 1 2 3 10 20 50 125 250 500 800 1000 4 6 Data Phase Bit Rate of CAN FD message Bit Rate kbps 4 5 6 100 125 250 5...

Страница 16: ...sage to from the fiber this LED flashes once FB_Err Orange If the I 2533T FD detects the RXD line of the fiber is off this LED is always on CAN_Err Red 1 If the I 2533T FD detects the bus off status o...

Страница 17: ...ends by two terminal resistors as in the following figure According to the ISO 11898 2 spec each terminal resistor is 120 or between 108 132 The bus topology and the positions of these terminal resist...

Страница 18: ...switch statuses present the condition if the terminal resistor is active default or inactive Figure 2 6 3 Adjustment of Terminal Resistance Generally if your application is as follows we recommend yo...

Страница 19: ...p ID The CAN port with the same Group ID setting can communicate with each other via fiber optics This setting is used for I 2533T FD to communicate with the others modules on star topology applicatio...

Страница 20: ...with each other Table 2 7 2 Group of Module Group ID Items Device A Group ID value Device B Group ID value 1 00 00 2 01 01 or 03 3 02 02 or 03 4 03 01 or 02 or 03 For example there are three CAN netwo...

Страница 21: ...r Bridge User Manual version 1 0 0 Page 21 Copyright 2021 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 2 8 Wire Connection The wire connection of the I 2533T FD is displayed below Figu...

Страница 22: ...3 1 1 Recommended DC parameter for CAN Bus Line Wire Cross Section mm2 Resistance km 0 25 AWG23 90 0 5 AWG20 50 0 8 AWG18 33 1 3 AWG16 20 Under the condition described above users can refer to the fol...

Страница 23: ...um 2km fiber length for each kind of CAN baud theoretically Although the maximum fiber length has no relationship with the CAN baud rate but some fiber attributions such as attenuation still influence...

Страница 24: ...Install the I 2533CS FD Utility Step 1 Get the I 2533CS FD Utility The software is located at https www icpdas com en download show php num 2454 model I 2533T FD Step 2 Install NET Framework 3 5 compo...

Страница 25: ...l version 1 0 0 Page 25 Copyright 2021 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 2 Select the installation path of the I 2533CS FD Utility and click the Next button 3 Confirm the in...

Страница 26: ...FD CAN CAN FD to Multi mode Fiber Bridge User Manual version 1 0 0 Page 26 Copyright 2021 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 4 Installation complete Click the Close button t...

Страница 27: ...the utility tool please follow the following steps to set up the communication between the Utility and the I 2533T FD Here is the example for the I 2533T FD configuration Step 1 Connect the PC availa...

Страница 28: ...l service icpdas com 4 3 Start to use I 2533CS FD Utility tool Figure 4 3 1 Main frame of the I 2533CS FD Utility tool Normal Settings This field is used to get the current module settings set user de...

Страница 29: ...2021 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 4 3 1 Connect to the module Press the Refresh button to scan and list all the necessary I 2533T FD modules on Module Name location The...

Страница 30: ...settings of module will be listed on Current Settings frame Current Settings Firmware Version Firmware version of the I 2533T FD module Group ID Group ID setting of the I 2533T FD module CAN baud rat...

Страница 31: ...unication baud rate in the CAN Port Settings field All settings will take effect after reboot the module The detailed functions are as follows CAN Mode CAN FD Set the CAN port into CAN FD mode When se...

Страница 32: ...ease refer to appendix 6 3 for CAN Status definition 2 CAN Error Counter item 0x value in hexadecimal format Please refer to appendix 6 4 for CAN Error Counter definition 3 CAN Buffer Status item 0x v...

Страница 33: ...ce icpdas com 5 EP CAN Error passive status 0 The CAN is in Error_Active state 1 The CAN is in the Error_Passive state 6 BO CAN Bus Off status 0 The CAN is not in Bus_OFF state 1 The CAN is in the Bus...

Страница 34: ...e Frame is used to reject remote standard extended CAN frame And the Standard ID Extended ID field are used to set accepted standard extended CAN IDs All settings in the CAN Filter Setting will take e...

Страница 35: ...d IDs button Set the CAN Standard Extended IDs setting on Standard Extended ID Fiter frame into the module 3 Re Init CAN button All settings in the CAN Filter Setting will take effect after pressing R...

Страница 36: ...Step 2 Set the I 2533T FD s pin 10 of 10 pin dip switch to ON position 10 pin dip switch Pin Switch Function Description 10 Firmware upgrade mode ON Into firmware upgrade mode OFF Into normal operatin...

Страница 37: ...Device and one more USB Disk window will pop up on the PC side Then users can upgrade the firmware of the I 2533T FD module via this USB disk Step 6 Get the Firmware Update Tool and firmware fire The...

Страница 38: ...Bridge User Manual version 1 0 0 Page 38 Copyright 2021 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com Step 8 Select USB port and the necessary USB Disk of PC Step 9 Press the the Brows...

Страница 39: ...ce icpdas com Step 10 Press the Firmware Update button to update the firmware After successfully to update the firmware the Firmware Update Success Please Reboot Module information will be display on...

Страница 40: ...40 Copyright 2021 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 6 Appendix 6 1 Revision History This chapter provides revision history information to this document The table below show...

Страница 41: ...I 2533T FD CAN CAN FD to Multi mode Fiber Bridge User Manual version 1 0 0 Page 41 Copyright 2021 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 6 2 Dimension...

Страница 42: ...wanted to send a dominant level data or identifier bit logical value 0 but the monitored bus value was recessive During Bus_Off recovery this status is set each time a sequence of 11 recessive bits ha...

Страница 43: ...lue Description 7 0 TEC Transmit error counter Current value of the transmit error counter maximum value 255 14 8 REC Receive error counter Current value of the receive error counter maximum value 127...

Страница 44: ...224 882 3529 869 5652 857 1429 65 845 0704 833 3333 821 9178 810 8108 800 000 70 789 4737 779 2208 769 2308 759 4937 750 000 75 740 7407 731 7073 722 8916 714 2857 705 8824 80 697 6744 689 6552 681 81...

Страница 45: ...2 283 0189 281 6901 280 3738 279 0698 210 277 7778 276 4977 275 2294 273 9726 272 7273 215 271 4932 270 2703 269 0583 267 8571 266 6667 220 265 4867 264 3172 263 1579 262 0087 260 8696 225 259 7403 25...

Отзывы: