Step 2: Match the I/O module and then get the I/O configuration 

information 

 

i.  Click the 

Refresh 

button to match the I/O modules to configuration of the controller 

 
 

 

 

 

 
 
 

 
 
 

 
 
 

 

 
 
 
 
 

 
 
 
 

 
 
 

 
 
 

 

ii.  Select the 

About 

option from the 

Help 

menu to get the I/O configuration and 

firmware information 

iii. Check the module status diagram, ensuring for the I/O modules to be matched 

 
 

 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

i. Click the 

Refresh

 button

 

ii. Select the 

About

 option  

from the 

Help

 menu

 

iii. See the module status diagram,  

ensuring for the I/O modules to  

be matched

 

Содержание ET-8KP4-MTCP

Страница 1: ...provide information needed to get started Please also consult the User Manual for detailed information on the setup and use of ET 8KPn MTCP In addition to this guide the package includes the following...

Страница 2: ...e of 50mm between the ET 8KPn MTCP and the top and bottom side of the enclosure panels must be provided 2 Connecting to PC Network and Setting up the Power i Connect PC to LAN1 port through a hub The...

Страница 3: ...ration process ensure that the LAN1 are used to connect to network and make the controller under the running firmware mode The default IP addresses are as follows Item LAN1 default IP Address 192 168...

Страница 4: ...settings iv Click the OK button to save the configuration 5 Inserting and Wiring the I O Modules There are various types of I O expansion modules for interfacing many different field devices to the E...

Страница 5: ...en the ET 8KPn MTCP and PC Laptop via the Modbus TCP protocol Step 1 Run the Modbus Utility and connect to ET 8KPn MTCP i Double click the Modbus Utility shortcut on the desktop ii Click the Modbus TC...

Страница 6: ...O modules to configuration of the controller ii Select the About option from the Help menu to get the I O configuration and firmware information iii Check the module status diagram ensuring for the I...

Страница 7: ...uration get the I O values and then save the I O configuration i Configure the I O settings such as Range Code Power on and Safe values ii Select the Timer Interval from the Monitor menu to set the mo...

Страница 8: ...g tables iv Select File option from the Save menu and select a location where the configuration file is about to be saved This operation can save the controller configuration and I O settings to an in...

Отзывы: