PET-7H16M Series User Manual, version 1.0.1 P.31
3.1.
Continuous Acquisition
Software AD Trigger
3.1.1.
In continuous acquisition and software AD trigger, Send a start command from PC over the
Ethernet to PET-7H16M to start the AD conversion. The analog input value is continuously
acquired and converted to digital data. The data accumulated to a network packet size returns to
the PC. The process of acquiring data is continuous until a stop command is sent over the
Ethernet.
The sample rate can range from 1 to 30K Hz on local networks. (Lower over the Internet or
wireless networks).
There are parameters below that need to be specified:
Sampling rate (1~30KHz)
Scan channels
The trigger mode is software AD trigger
Ethernet
AI0
AI7
…
Software trigger
DMA
Internal Clock
CON1
PGA
Sampling
Hold
FIFO
Memory
ADC
Содержание ET-7H16M Series
Страница 1: ...ET 7H16M Series User Manual Version 1 0 1 January 2019 Written by Sean Hsu Edited by Anna Huang...
Страница 20: ...1 5 Block Diagram PET 7H16M functions are illustrated in the block diagram shown here...
Страница 32: ...PET 7H16M Series User Manual version 1 0 1 P 32...
Страница 34: ...PET 7H16M Series User Manual version 1 0 1 P 34...