DB –24P/24PD
11.5. Jumper setting
If you are using AC signal, You must short the AC FILTER jumper.
If you are using DC input signals, the AC FILTER is optional. If the
response time of input signals less than 20
µ
s, set the filter off. If you want
a slow response (about 5 to 10 ms) for rejecting noise or contact bouncing,
short the AC FILTER jumper.
With filter for AC signal
Without filter for DC signal
Photo-Couple
User’s Manual for DIO Daughter Boards (Ver.2.5, Jan/2004 )
52
Содержание DB-16R
Страница 19: ...DB 16P8R 4 2 Board Layout User s Manual for DIO Daughter Boards Ver 2 5 Jan 2004 18...
Страница 20: ...DB 16P8R 4 3 External Power Relay Output Relay Output User s Manual for DIO Daughter Boards Ver 2 5 Jan 2004 19...
Страница 52: ...DB 24P 24PD 11 4 Layout DB 24P DB 24PD User s Manual for DIO Daughter Boards Ver 2 5 Jan 2004 51...