ALM-Horn Series User’s Manual

 

 

ALM-Horn Series 

User’s Manual (Rev1.0, NOV/2020) ------------- 19

 

 

Static IP: 

 

 

IP: 

Specific an IP that is not been used. 

 

 

Mask: 

Default will be 

255.255.255.0

 

 

Gateway: 

Basically define in the AP you are going to connect. 

 

SSID

 

Service  Set  Identifier:  Connected  devices  must  be  the  same  SSID,  SSID 
length must not exceed 31 characters.

Key Type

 

Key of Encryption, connected devices must with the same Key. 
Open     

 

No Key request. 

WEP(Shared)   

Key length must be 15 characters. 

WPA/WPA2-PSK 

Key length must between 8~15 characters. 

 

Table 3-2

Station SSID & Key type configure 

 

Wi-Fi Mode

 

ALM Controller working mode (default is in

 

AP

 

 

AP (

Access Point

)

 

PC or Android Device connect to ALM Controller directly through  

AP(Fixed IP:

192.168.77.1

), AP mode support only one connection, If Multiple 

devices connect at a same time, only first connected  devices can access. 

STA(

Station

): 

ALM Controller will auto connect to specific Wi-Fi AP, PC or Android 

Device also need to connect to the same AP, then they can use those ALM 
Controller in same domain. 

*. Please check specific Wi-Fi AP is active and SSID/key is same as the setting 
before use. 

 

Location information: 

Set the information for you to identify & locate those Controller easily, length 

must under 31 characters. 
 

Modbus Port: 

Modify Modbus TCP Port (default is 

502

 

Modbus Idle Timeout: 

Set Idle Timeout for Modbus TCP connection (default is 

120 Sec

) in 

STA(Station) mode, recommend 30 Sec. when device in STA mode connect to an 
AP, Host device break connect with AP and lost connection, the device will hang in 
a dead connection. To prevent this happen, set a timeout, the device will close the 
connection and wait for next connect. 

Содержание ALM-Horn Series

Страница 1: ...resulting from the use of this product ICP DAS reserves the right to change this manual at any time without notice The information furnished by ICP DAS is believed to be accurate and reliable However...

Страница 2: ...ALM Horn Series User s Manual ALM Horn Series User s Manual Rev1 0 NOV 2020 2 Document Revision Version Date Description of changes Rev1 0 2020 11 04 First release for ALM Horn Series...

Страница 3: ...es 11 2 3 Dimensions 12 2 4 Wire Connection 13 2 4 1 Wire connection define 13 2 4 2 I O connection 13 3 Software 15 3 1 ALM Utility for ALM Horn WF AP Mode 15 3 1 1 Main Screen 15 3 1 2 Controller St...

Страница 4: ...U protocol ALM Horn series device includes 1 channel digital input for any dry contact output such as SA BA FA etc and 1 channel digital output Each device has 4 kinds of alarm tone NC NO input mode s...

Страница 5: ...ice accepts any dry contact to trigger DI input when the alarm been trigger it output from Piezo Transducer LED s open collector DO ALM Horn series include 4 kinds of alarm tone the DIP switch s selec...

Страница 6: ...Dry Contact Sink Dry Contact Level NO Open NC Close to GND Photo Isolation 3750 VDC Input Condition Pulse Width must 200mSec or more Digital Output Channels 1 Output Type Open Collector Sink Max Load...

Страница 7: ...m status Protection Waterproof IP43 Panel Mount Upright Position ESD IEC 61000 4 2 8 kV Air for Random Point EFT IEC 61000 4 4 2 kV for Power Environment Operating Temperature 20 75 C Mechanism Dimens...

Страница 8: ...Series User s Manual ALM Horn Series User s Manual Rev1 0 NOV 2020 8 2 Hardware 2 1 Outward Appearance Figure 2 1 Front Panel Figure 2 2 Back Panel Connector Piezo Transducer output Waterproof membran...

Страница 9: ...M Horn Series User s Manual ALM Horn Series User s Manual Rev1 0 NOV 2020 9 2 1 2 Connector Pin Define Figure 2 3 I O Connector of ALM Horn MRTU BR Figure 2 4 I O Connector of ALM Horn BR ALM Horn WF...

Страница 10: ...g Figure 2 5 Switches on the PCB 2 2 1 Reset to default for ALM Horn WF BR only Remove the back panel Press hold the Reset button on the bottom side over 6 Sec until the Red LED Status Alarm quick fla...

Страница 11: ...ries Figure 2 6 Alarm Tone select switch for DI trigger alarm Figure 2 7 DI Input Mode NO NC select switch Note Change the Input Mode NC NO must restart the power to take effect Dip Switch Switch Inde...

Страница 12: ...es User s Manual Rev1 0 NOV 2020 12 2 3 Dimensions The diagrams below provide the dimensions of the ALM Horn series to use in defining your enclosure specifications All dimensions are in millimeters F...

Страница 13: ...n Series User s Manual Rev1 0 NOV 2020 13 2 4 Wire Connection 2 4 1 Wire connection define The following describe the wire color Figure 2 9 Wire color 2 4 2 I O connection 2 4 2 1 Digital Input DI wir...

Страница 14: ...ual ALM Horn Series User s Manual Rev1 0 NOV 2020 14 2 4 2 2 Open Collector Digital Output DO wiring Figure 2 11 Open Collector Output wiring 2 4 2 3 RS 485 wiring for ALM Horn MRTU Figure 2 12 RS 485...

Страница 15: ...Horn WF ALM Utility available on both Windows Android application to operating and configure the ALM Horn WF Utility Support Windows 7 or later versions and Android 5 0 or later versions The followin...

Страница 16: ...1 2 Controller Status Show the connected controller information user define Locate string RSSI strength Device IP Static IP button for changing device IP in STA mode 3 1 3 DI DO Status Control Show t...

Страница 17: ...1 4 Icon Button ICON function Setup Open the Setup Screen Android versions Setup function under the icon Find Controller Red Led blinking use to find the connected Controller Refresh Refresh status M...

Страница 18: ...e take effect on new setting AP SSID Name 1 Default Controller s SSID in Wi Fi AP mode will be ALM 06 xxxxxx Note xxxxxx is the last 6 characters MAC address of your device Key Type AP mode SSID Key t...

Страница 19: ...7 1 AP mode support only one connection If Multiple devices connect at a same time only first connected devices can access STA Station ALM Controller will auto connect to specific Wi Fi AP PC or Andro...

Страница 20: ...P Scanner for Windows Network Analyzer for Android those are high performance scanner tools on each OS 3 2 USB Utility for ALM Horn MRTU The Utility provides the simple way to configuration ALM Horn M...

Страница 21: ...ata contents of registers Function Code Descriptions 01 0x01 Read Coil Status 02 0x02 Read Input Status 03 0x03 Read multiple Analog Output registers 05 0x05 Force Single Coil 06 0x06 Write single Ana...

Страница 22: ...nary A binary item is represented as a single bit within a data word All binary is packed into 16 bits data words which are accessed using function code 01 and 02 Therefore a single register contains...

Страница 23: ...P Application Data Unit 4 3 1 MBAP The Modbus TCP extension includes 7 additional bytes to the original Modbus protocol which allows for transport over the TCP IP layers A dedicated header is used on...

Страница 24: ...F 1 ON R Table 5 7 FC02 Read DI address 1xxxx Address CH Length Descriptions Range Value Access Type 40011 Always 1 Read Idle Timeout value 16bit Word R Table 5 8 FC03 Read multiple AO address 4xxxx A...

Страница 25: ...eries User s Manual ALM Horn Series User s Manual Rev1 0 NOV 2020 25 Technical Support If you have problems about using the ALM Horn Series device please contact ICP DAS Product Support Email service...

Отзывы: