2.4.4 D/I Input Buffer Register
(READ) Base+6 : D/I Input Buffer Low Byte Data Format
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
D7 D6 D5 D4 D3 D2 D1 D0
(READ) Base+7 : D/I Input Buffer High Byte Data Format
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
D15 D14 D13 D12 D11 D10 D9 D8
D/I 16 bits input data : D15..D0, D15=MSB, D0=LSB
The A-812PG provides 16 TTL compatible digital inputs. The low 8 bits are stored in
address BASE+6. The high 8 bits are stored in address BASE+7.
2.4.5 Clear Interrupt Request
(WRITE) Base+8 : Clear Interrupt Request Format
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
X X X X X X X X
X=don‘t care, XXXXXXXX=any 8 bits data is validate
If A-812PG is working in the interrupt transfer mode, an on-board hardware status bit will be
set after each A/D conversion. This bit must be
clear by software
before the next hardware
interrupt. Writing any value to address BASE+8 will clear this hardware bit and the
hardware will generate another interrupt when next A/D conversion is completed.
A-812PG Hardware Manual (Ver.1.2, Sep/2005, IPH-004-12) -----
19