MVS6000 System Level Manual/1.0/Dec-2001
3.4 MMI
On the MVS600x, the MMI behaves differently regarding:
·
the illumination settings (see page 4-3)
·
the booting of the boards (see below).
Pool Parameters
A new section is added in pool.txt, namely the [MVS6000Boot] section:
[MVS6000Boot]
BootOnStartup=1
TimeoutOnPollingForSyncFile=30
BootOnStartup
is set to
1
, which means that the MVS6000 boards are booted at MMI startup (and
are reset when MMI exits).
TimeoutOnPollingForSyncFile
is the time the MMI waits for the MVS6000 boards to boot. In case
other software is running on the same PC, you may increase this parameter.