iCool Compact Series  |  Owners Manual

Trouble shooting

 The most common issue that can prevent successful operation is lack of water flow. The touch screen 

lights will turn 

ORANGE

 if this happens. 

It can also occur if air is trapped in the water pipes or the pump, or if flow is restricted by a blocked water 
inlet. The MiPod will attempt to clear it automatically several times by surging the pump to dislodge the 
trapped air or debris in the pipes. If after several attempts it can not correct the lack of water flow, it will 
shut the machine down and warn you that action must be taken to correct it. 

Water Flow Alarm

Your MiPod will attempt to correct any water flow problems, but occassionall this may not be 

possible.

An explanation will appear in the middle of the screen to notify you that the chiller has stopped.

Your MiPod can not continue until the reason for the lack of water is found. This is important because 
such a powerful machine could easily freeze the remaining water in the titanium heat exchanger tanks 
solid and that could cause serious damage. The operating system will not allow that to happen.

Содержание iCool Compact Iceman

Страница 1: ...Page iCool Compact Series Owners Manual 01 iCool 2021 MIPOD Series Owners Manual icoolsport com info icoolsport com ...

Страница 2: ...Page iCool Compact Series Owners Manual 02 ...

Страница 3: ... System Settings Starting Up Heat Mode Product use Requirements How to Use Page 05 Page 09 Page 12 Page 11 Page 06 Page 08 Index Starting Up Chill Mode Page 10 Session Timer Page 13 01 03 05 07 Trouble shooting Page 14 Specifications Page 06 and 20 09 Support Page 22 02 04 06 08 10 11 ...

Страница 4: ...04 MiPod Pro UPDATED PICTURE NEEDED HERE ...

Страница 5: ...ng cost of around 30 50c a day is all it uses to keep your water at your desired ice bath or recovery temperature ready for use anytime day or night whenever you need it No waiting This revolutionary new iCool MiPod range combines the latest technology in materials science the latest advances in refrigeration technology and the very latest in touch screen based electronics and control systems all ...

Страница 6: ...rnal steps and fully enclosed An alternative version is also available for the pool to be connected to a remote chiller heater that can be placed in any convenient place nearby This version is ideal where the MiPod is installed in a small room or where several MiPods are installed in the same room to keep all sound and heat generated by the cooling systems away from the pool An optional stainless ...

Страница 7: ...e sure it is correctly positioned and level Essential Ventilation The large rear vent and both side vents must be at least 300mm 1 foot from all walls or obstruction to allow enough cooling airflow to the refrigeration sytem or it may overheat and cause the safety system to shut it down Your MiPod has many safety features built in it will stop if it has no water or if it is too hot The screen will...

Страница 8: ...water Fill pool with water but allow enough space above the water to handle the water displacement and prevent overflow when users enter the pool This is particularly important if you intend to have 2 or 3 people use the MiPod Pro at the same time 3 people will displace a lot of water A permanent water connection is not required Simply fill your MiPod with a hose Once it s filled up turn the main ...

Страница 9: ... If this happens then after a short time a small blue square appears at the top left of the screen as shown below Simply tap anywhere on this small blue square to connect manually Do not touch anything in the narrow blue band on the left hand side this is for service settings only The Main Operating Screen Will Now Appear MENU ITEMS AUTOMATIC START BUTTON THE CURRENT POOL TEMPERATURE TEMPERATURE S...

Страница 10: ...TART Button The system s computer takes over and enters the fully automatic mode It will now operate the chiller to achieve your selected temperature and when it is reached it will hold it accurately for as long as you wish Intelligent Water Flow correction If the water does not flow steadily when you first start up due to air being trapped somewhere in the plumbing or inside the water pump your i...

Страница 11: ...sible with the DT Dual Temp or heat only models Continuous Always Available Operation Your MiCool has been manufactured using quality components from the world s leading manufacturers and is therefore capable of continuous 24 7 operation Therefore if you wish to have your pool available at your desired temperate at any time of the day or night then you can leave it running continuously at very low...

Страница 12: ...machine choose SETTINGS from the list You can change between Centigrade and Fahrenheit You can select the volume of the System Sounds You can change the appearance from Dark Mode to Light Mode You can set levels of energy saving Level 5 provides the most efficient cooling heating Changing Basic System Settings ...

Страница 13: ...ION TIMER This allows you to pre set the amount of time athletes should remain in the pool It provides a count down on the screen It sounds a warning at the end of the session It can automatically re set and begin again for the next athlete The Change Over time between athletes can also be pre set ...

Страница 14: ...ter several attempts it can not correct the lack of water flow it will shut the machine down and warn you that action must be taken to correct it Water Flow Alarm Your MiPod will attempt to correct any water flow problems but occassionall this may not be possible An explanation will appear in the middle of the screen to notify you that the chiller has stopped Your MiPod can not continue until the ...

Страница 15: ...ear if the MiPod is unable to correct the water flow Problem in Itself In this case you must take further action to correct the problem If it can fix the water flow automatically then this message will appear No action is needed it will continue to operate correctly ...

Страница 16: ...arge main fan may continue to run for some time even after a shut down until the temperature is safely back to normal For the safety of users any leakage of even a small amount of electrical current will instantly cause the Residual Current Device to remove all electrical power from the entire system The maximum leakage allowed is 30 milliamperes which is considered to be a generally harmless leve...

Страница 17: ...s more than 45ºC eventually the system will reach the limit of its safe operating range If the temperature inside the cabinet reaches 68ºC the safety system will shut it down sound an alarm and display the warning screen The screen will give advice as to when it can be safely restarted This may incur if the airflow is blocked by being placed too close to a wall or if an object such as a bath towel...

Страница 18: ...c feet of air per minute Air flow must never be blocked by any object On very hot days when the air temperature is more than 45ºC it may not be possible to run the system at full power due to the excessive heat If the temperature inside the unit exceeds 68ºC the over heat safety circuit will operate and shut it down This may occur either in very hot weather or if the airflow is blocked by being pl...

Страница 19: ...Page 19 iCool Compact Series Owners Manual ...

Страница 20: ...Yes Yes Yes Hi Resolution LCD Colour Touch Screen 13 Inch High Definition 13 Inch High Definition 13 Inch High Definition 13 Inch High Definition 10 Inch High Definition Electrically Isolated Pump Supplied by built in R C D Supplied by built in R C D Supplied by built in R C D Supplied by built in R C D Supplied by built in R C D Air Flow Capacity Low Noise 2000 Cubic Ft per Minute Low Noise 2000 ...

Страница 21: ...feedback and suggestions and we offer support for general inquiries and information for specific countries on our website at icoolsport com Notes About Specifications Thank You For Choosing iCool The World s Most Popular Ice Bath Therapy And Recovery Systems Materials MiPods Cabinet and Chassis Carbon Fibre and fibre glass resins Coatings 2 part epoxy multi layer surface coating Heat Exchanger Tit...

Страница 22: ...er printed on the Rating Label affixed to the machine Retailer Country and Name Date of Purchase and Proof of Purchase required Warranty Justemailusatinfo icoolsport com and we will respond with assistance usually the same day As our factory and service staff are based in Australia please allow for a short delay due to time zone differences We also have representatives in many countries who can of...

Страница 23: ...Page 23 iCool Compact Series Owners Manual The industry leader in ice bath technology ...

Страница 24: ...Page 24 iCool Compact Series Owners Manual info icoolsport com 61 428 944 741 BurleighHeads GoldCoast Australia Representatives around the world icoolsport com ...

Отзывы: