iCool Compact Series | Owners Manual
This is a very rare issue, but if the screen freezes
while the MiPod is running normally, the main
computer will usually still carry on running the
system and monitoring the safety features but
you will not be able to change anything and the
displayed temperatures will not update. You can
either allow it to keep running if that is more
convenient, or you can restore the system to
normal operation by switching off the main
power and re starting.
If the problem persists please contact iCool at
[email protected] for advice.
The cooling unit inside your MiPod can move
large amounts of heat per hour. Naturally this
heat has to be removed into the air surrounding
the system. The powerful fan can normally
handle this with ease, however if the air flow
around the MiPod is restricted so that the heat
can not escape, or the outside air temperature
is more than 45ºC, eventually the system will
reach the limit of its safe operating range.
If the temperature inside the cabinet reaches
68ºC the safety system will shut it down, sound
an alarm and display the warning screen. The
screen will give advice as to when it can be
safely restarted. This may incur if the airflow is
blocked by being placed too close to a wall or if
an object such as a bath towel is blocking the
air flow.
Cooling a pool that has previously been heated
can also cause a heat overload warning and
shut down. This will only occur if the pool is still
above 30-35ºC. It is good practice to allow the
heat to reduce naturally to below 30ºC before
starting the cooling cycle. This also saves a lot
of electricity.
Always make sure that all vents are not covered
or restricted and that the area has a good flow
of fresh air. Never place the side of the MiPod
closer than 300mm (12 inches) from a wall or
other obstruction that could restrict the flow
of cooling air.
If Your Screen Freezes Or Fails To
Respond
If The iCool Shuts Down And Displays
A “System Too Hot” Red Warning
Screen