Flow Totalizer
Display the Current Value of Flow Totalizer : Range 0~99,999,999
1. Hold the key for 3 seconds to show current value of the 7th – 8th digits
2. After releasing the key the current value of the 1st – 6th digits will be displayed
Alarm Limit of Flow Rate Meter
How to Set the Alarm Limit of Flow Rate Meter?
The
Flow Total
|
Totalizer
can be protected from an accidental reset. To set lockout program set any number
from 0-9 excluding "5". The factory default unlock number 5.
Totalizer Reset —▶ Press both & keys together for
🕓
3 Sec.
Low Battery Notification
Displaying Flow Rate | Flow Totalizer
Voltage of Battery
Symbol
Status
3.0V
Full Scale
< 3.0V
Mild Scale
< 2.8V
Low Scale
(Pilot BAT Flashing)
< 2.6V
Low Voltage
(Pilot BAT & Display Flashing)
In-Line Paddle Wheel Flow Meter
7
23-0107 © Icon Process Controls Ltd.
r indicates Default Flow Rate Mode
Mode of Operation
(Eco) = Extended Battery Life
Highlighted to Indicate
Programmed Unit of Measurement
Press and hold for 3 sec
to change from
Flow Rate
to
Flow Total
Battery Life
Flow Total
Flow Rate
Press and hold for 3 sec to view
8 + 9 digits while in
Totalizer Screen