background image

iCON 

iSOLAR 3”

 PDP Instruction Manual

   

 

 

 

6.   Kit Contents and Technical Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model 

Part 

No 

Motor kW/hp 

Hmax 

Controller 

Solar Array 

Vmp 

Max 

VOC 

Max 

Amps 

PDP3 250 

808691 

0.25kW / 1/3hp 

60m 

24V 

1 x 300W 

18 

 40V 

48V 

15A 

PDP3 370 

808692 

0.37kW / 1/2hp 

80m 

48V 

2 x 300W in series 

40 

 76V 

96V 

15A 

PDP3 750 

808694 

0.75kW / 1hp 

140m 

96V 

3 OR 4 x 300W in 

series 

80 

 150V 

180V 

15A 

 

Solar array recommendation indicative only 

Solar inputs must respect the Voc and Max Current (Amperage) values 

 

 

Solar Panels

 and their mounting system (where applicable) are supplied 

separately and come with their own instructions.

 

The Max Voc and Max Current (A) capabilities of the motor and the controller must always be 
respected. Fitting additional or incorrectly rated panels will cause serious harm or irreparable 
harm to the controller and motor voiding warranty. 

A.  Isolator Switch

 

with M/F MC4 solar connecters.

 

B.  PDP3 Solar Controller

 

matched to suit the applicable pump model.

 

 

D.  Check/Non-return Valve

 

1” 

BSPF.  

 

G.  iSOLAR PDP3 helical rotor pump and motor

 

fitted with  

       30m 2.5mm

2

 power cable including earth and supplied with a 

       weather-proof 4 Pin (IP54 rated) plug. Outlet 1

” BSP

M.

 

E.  Low voltage, low water float

 

fitted with 30m cable to 

      provide low water level protection.

 

C.  Earth Strap 

2.5m long, 4mm

2

. Connects externally to the controller. 

A

 

B

 

C

 

G

 

F.  30m nylon safety rope

 

D

 

F

 

E

 

Maximum Pump Submergence is 100m 

Содержание iSolar 808691

Страница 1: ...l Solar Pump Complete Solution Kit 808691 BIA PDP3 SOLAR250 808692 BIA PDP3 SOLAR370 808694 BIA PDP3 SOLAR750 Brushless submersible helical motor iCON PDP3 Solar Controller 30 meters cable Non return...

Страница 2: ...Electrical Connections 6 7 8 Display 8 9 Display Functions Explained 8 10 Alarm Parameters and Meaning 9 11 Installation 10 13 12 Operation summary 14 13 Warranties Terms and Conditions 15 2 ISO 7010...

Страница 3: ...r pumps can produce extremely high pressures and any electrical energy must always be treated with care Stay safe and get the important details right so you can enjoy the benefits of your purchase 4 K...

Страница 4: ...for the internal electronics to discharge before opening the cover The controller is IP65 rated but should not be exposed to direct sunlight Install the controller where it has excellent ventilation a...

Страница 5: ...tructions The Max Voc and Max Current A capabilities of the motor and the controller must always be respected Fitting additional or incorrectly rated panels will cause serious harm or irreparable harm...

Страница 6: ...the controller before removing the cover to access the low voltage circuit connections The controller is IP65 rated It should not be exposed to direct sunlight Install the controller where it has exce...

Страница 7: ...p to x Meters Watts Panels Max VOC Vmpp Amps 10 25 30 50 75 100 CROSS SECTION MM2 300 1 x 300 48V 35 10 2 5 2 5 2 5 6 10 10 600 2 x 300 96V 70 10 2 5 2 5 2 5 2 5 4 6 900 3 x 300 150V 105 10 2 5 2 5 2...

Страница 8: ...ration Press again to turn the pump controller off To see if the pump is running press SWITCH to display RPM SWITCH Display Scroll Repeated presses scroll through real time operating values Voltage Pu...

Страница 9: ...causes P0 Hardware over current Motor and Controller mismatched Motor short circuit or cable damage P43 Phase protection Motor phase absence or U V W wiring issue P46 Stall protection Motor and Contr...

Страница 10: ...10 iCON iSOLAR 3 PDP Instruction Manual 11 Installation...

Страница 11: ...perature has an impact on pump performance Recommended water temperature of 10 to 40 C A check valve is included with the kit It must be installed on the pump outlet or at the well head Additional che...

Страница 12: ...to assist your decision regarding the best angle for your situation As a rule of thumb solar panels should be more vertical during winter to gain most of the low winter sun and flatter during summer...

Страница 13: ...example The pressure loss values per 100m of pipe length are for 16 bar rated pressure supply pipe at 25lpm Pipe size Friction loss per 100m of pipe at 25 lpm If unsure increasing the pipe size by on...

Страница 14: ...on cloudy days The display values will be constantly changing as the pump adjusts to optimise the output based on the available input power Note that the wattage value indicates what the pump is curre...

Страница 15: ...nd Consumer Act 2010 Cth for goods purchased in Australia and the Consumer Guarantees Act 1993 NZ for goods purchased in New Zealand 4 Our goods come with guarantees that cannot be excluded under the...

Страница 16: ...or changes in product specifications 2020 Copyright White International Pty Ltd TM WARNING Please be aware that various brands products depicted within this document are subject to trademark patent or...

Отзывы: