6. Kit Contents and Technical Specifications
Model
Part
No
Motor kW/hp
Hmax
Controller
Solar Array
Vmp
Max
VOC
Max
Amps
PDP3 250
808691
0.25kW / 1/3hp
60m
24V
1 x 300W
18
–
40V
48V
15A
PDP3 370
808692
0.37kW / 1/2hp
80m
48V
2 x 300W in series
40
–
76V
96V
15A
PDP3 750
808694
0.75kW / 1hp
140m
96V
3 OR 4 x 300W in
series
80
–
150V
180V
15A
Solar array recommendation indicative only
Solar inputs must respect the Voc and Max Current (Amperage) values
Solar Panels
and their mounting system (where applicable) are supplied
separately and come with their own instructions.
The Max Voc and Max Current (A) capabilities of the motor and the controller must always be
respected. Fitting additional or incorrectly rated panels will cause serious harm or irreparable
harm to the controller and motor voiding warranty.
A. Isolator Switch
with M/F MC4 solar connecters.
B. PDP3 Solar Controller
matched to suit the applicable pump model.
D. Check/Non-return Valve
1”
BSPF.
G. iSOLAR PDP3 helical rotor pump and motor
fitted with
30m 2.5mm
2
power cable including earth and supplied with a
weather-proof 4 Pin (IP54 rated) plug. Outlet 1
” BSP
M.
E. Low voltage, low water float
fitted with 30m cable to
provide low water level protection.
C. Earth Strap
2.5m long, 4mm
2
. Connects externally to the controller.
A
B
C
G
F. 30m nylon safety rope
D
F
E
Maximum Pump Submergence is 100m