background image

iCON 

iSOLAR 3”

 PDP Instruction Manual

   

 

 

13 

 

11. Installation cont.

 

 

Pressure pipe selection 

Helical rotor type pumps such as the iSOLAR PDP are able to generate very high 
pressures, particularly if they continue to operate in a no-flow situation. 

Where practical, an open loop system is desirable. 

 

Model

 

Hmax

 

Approx. pressure Bar/PSI

 

PDP3 250 

60m 

5.7 / 82.6 

PDP3 370 

80m 

7.8 / 113.1 

PDP3 750 

140m 

13.7 / 198.7 

 

  Select and use suitably pressure rated water delivery piping. 

  It is strongly recommended to fit a switching device to the delivery line to prevent closed 

head operation. 
 

 

Pressure pipe sizing 

The iSolar PDP3 range has a maximum output flow of 25 lpm so the resulting pipe friction 
losses are low. The correct pipe sizing allows for the possibility of very long delivery piping. 
 

The 

following table is a ‘worst possible case’ example. The

 pressure loss values per 100m of 

pipe length are for 16 bar rated pressure supply pipe at 25lpm. 

 

Pipe size

 

Friction loss per 100m  

of pipe at 25 lpm

 

 

If unsure, increasing the pipe 

size by one size will result in 

a substantial reduction to the 

pipe friction losses. 

MD

25

PN16 

14.60m 

MD

32

PN16 

4.55m 

MD

40

PN16 

1.56m 

MD

50

PN16 

0.53m 

Note this table does not automatically infer the need to use 16 bar pressure rated pipe.

 

 
 

Optional switching 

  An input connected to TL/TH and COM terminals allows the user to fit some form of switch 

such as a float in the destination tank to turn the pump off when the tank level has risen. 
Alternately, by fitting a double acting ballcock to the tank inlet a suitably adjusted pressure 
switch will turn off the pump when the ballock closes (tank full) and the pipe pressure rises 

 

  When the switch circuit stops the pump running, the LED on the controller l

abelled ‘TANK’ 

will illuminate. When the float or pressure switch circuit opens again pump operation will 
re-commence immediately.

 

 

Содержание iSolar 808691

Страница 1: ...l Solar Pump Complete Solution Kit 808691 BIA PDP3 SOLAR250 808692 BIA PDP3 SOLAR370 808694 BIA PDP3 SOLAR750 Brushless submersible helical motor iCON PDP3 Solar Controller 30 meters cable Non return...

Страница 2: ...Electrical Connections 6 7 8 Display 8 9 Display Functions Explained 8 10 Alarm Parameters and Meaning 9 11 Installation 10 13 12 Operation summary 14 13 Warranties Terms and Conditions 15 2 ISO 7010...

Страница 3: ...r pumps can produce extremely high pressures and any electrical energy must always be treated with care Stay safe and get the important details right so you can enjoy the benefits of your purchase 4 K...

Страница 4: ...for the internal electronics to discharge before opening the cover The controller is IP65 rated but should not be exposed to direct sunlight Install the controller where it has excellent ventilation a...

Страница 5: ...tructions The Max Voc and Max Current A capabilities of the motor and the controller must always be respected Fitting additional or incorrectly rated panels will cause serious harm or irreparable harm...

Страница 6: ...the controller before removing the cover to access the low voltage circuit connections The controller is IP65 rated It should not be exposed to direct sunlight Install the controller where it has exce...

Страница 7: ...p to x Meters Watts Panels Max VOC Vmpp Amps 10 25 30 50 75 100 CROSS SECTION MM2 300 1 x 300 48V 35 10 2 5 2 5 2 5 6 10 10 600 2 x 300 96V 70 10 2 5 2 5 2 5 2 5 4 6 900 3 x 300 150V 105 10 2 5 2 5 2...

Страница 8: ...ration Press again to turn the pump controller off To see if the pump is running press SWITCH to display RPM SWITCH Display Scroll Repeated presses scroll through real time operating values Voltage Pu...

Страница 9: ...causes P0 Hardware over current Motor and Controller mismatched Motor short circuit or cable damage P43 Phase protection Motor phase absence or U V W wiring issue P46 Stall protection Motor and Contr...

Страница 10: ...10 iCON iSOLAR 3 PDP Instruction Manual 11 Installation...

Страница 11: ...perature has an impact on pump performance Recommended water temperature of 10 to 40 C A check valve is included with the kit It must be installed on the pump outlet or at the well head Additional che...

Страница 12: ...to assist your decision regarding the best angle for your situation As a rule of thumb solar panels should be more vertical during winter to gain most of the low winter sun and flatter during summer...

Страница 13: ...example The pressure loss values per 100m of pipe length are for 16 bar rated pressure supply pipe at 25lpm Pipe size Friction loss per 100m of pipe at 25 lpm If unsure increasing the pipe size by on...

Страница 14: ...on cloudy days The display values will be constantly changing as the pump adjusts to optimise the output based on the available input power Note that the wattage value indicates what the pump is curre...

Страница 15: ...nd Consumer Act 2010 Cth for goods purchased in Australia and the Consumer Guarantees Act 1993 NZ for goods purchased in New Zealand 4 Our goods come with guarantees that cannot be excluded under the...

Страница 16: ...or changes in product specifications 2020 Copyright White International Pty Ltd TM WARNING Please be aware that various brands products depicted within this document are subject to trademark patent or...

Отзывы: