background image

     4 

 

        

 

   

iCON iSOLAR 

3”PDP Instruction Manual

 

 

 

 

5.   Warnings and Cautions

 

 

 

Please read the manual fully and carefully before starting. 
Retain the manual for future reference. 

 

Solar panels create electrical energy when exposed to light. 
At all times, treat solar panels as live and handle with care. 

 

Any  changes  or  modification  to  the  wiring  must  be  carried  out  by 
competent, skilled and suitably qualified personnel only. 

 

The 

iSolar 

PDP3  controller  has  internal  capacitors  that  MUST  be 

allowed  to  discharge  before  handling  the  motor.  Allow  2  minutes  for 
stored energy to dissipate before handling the pump/motor. 

 

Never  open  the  cover  while  controller  is  connected  to  an  electrical 
supply. Disconnect and allow 2 minutes for the internal electronics to 
discharge before opening the cover. 

 

The controller is IP65 rated but should not be exposed to direct sunlight. 
Install the controller where it has excellent ventilation away from direct 
sunlight or exposure to adverse weather. 

 

Solar arrays are an attractive earth path for lightning strikes. 
Ensure the panels and controller are well earthed. 

 

Helical  rotor  pumps  must  be  used  in  a  clean  water,  sediment-free 
environment.  Even  a  small  amount  of  sand  may  lead  to  screw  wear, 
jamming or performance degradation. 

 

This appliance is not intended for use by persons (including children) 
with  reduced  physical,  sensory  or  mental  capabilities,  or  lack  of 
experience and knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person responsible for 
their safety. Children should be supervised to ensure that they do not 
play with the appliance. 

 

 

 

Содержание iSolar 808691

Страница 1: ...l Solar Pump Complete Solution Kit 808691 BIA PDP3 SOLAR250 808692 BIA PDP3 SOLAR370 808694 BIA PDP3 SOLAR750 Brushless submersible helical motor iCON PDP3 Solar Controller 30 meters cable Non return...

Страница 2: ...Electrical Connections 6 7 8 Display 8 9 Display Functions Explained 8 10 Alarm Parameters and Meaning 9 11 Installation 10 13 12 Operation summary 14 13 Warranties Terms and Conditions 15 2 ISO 7010...

Страница 3: ...r pumps can produce extremely high pressures and any electrical energy must always be treated with care Stay safe and get the important details right so you can enjoy the benefits of your purchase 4 K...

Страница 4: ...for the internal electronics to discharge before opening the cover The controller is IP65 rated but should not be exposed to direct sunlight Install the controller where it has excellent ventilation a...

Страница 5: ...tructions The Max Voc and Max Current A capabilities of the motor and the controller must always be respected Fitting additional or incorrectly rated panels will cause serious harm or irreparable harm...

Страница 6: ...the controller before removing the cover to access the low voltage circuit connections The controller is IP65 rated It should not be exposed to direct sunlight Install the controller where it has exce...

Страница 7: ...p to x Meters Watts Panels Max VOC Vmpp Amps 10 25 30 50 75 100 CROSS SECTION MM2 300 1 x 300 48V 35 10 2 5 2 5 2 5 6 10 10 600 2 x 300 96V 70 10 2 5 2 5 2 5 2 5 4 6 900 3 x 300 150V 105 10 2 5 2 5 2...

Страница 8: ...ration Press again to turn the pump controller off To see if the pump is running press SWITCH to display RPM SWITCH Display Scroll Repeated presses scroll through real time operating values Voltage Pu...

Страница 9: ...causes P0 Hardware over current Motor and Controller mismatched Motor short circuit or cable damage P43 Phase protection Motor phase absence or U V W wiring issue P46 Stall protection Motor and Contr...

Страница 10: ...10 iCON iSOLAR 3 PDP Instruction Manual 11 Installation...

Страница 11: ...perature has an impact on pump performance Recommended water temperature of 10 to 40 C A check valve is included with the kit It must be installed on the pump outlet or at the well head Additional che...

Страница 12: ...to assist your decision regarding the best angle for your situation As a rule of thumb solar panels should be more vertical during winter to gain most of the low winter sun and flatter during summer...

Страница 13: ...example The pressure loss values per 100m of pipe length are for 16 bar rated pressure supply pipe at 25lpm Pipe size Friction loss per 100m of pipe at 25 lpm If unsure increasing the pipe size by on...

Страница 14: ...on cloudy days The display values will be constantly changing as the pump adjusts to optimise the output based on the available input power Note that the wattage value indicates what the pump is curre...

Страница 15: ...nd Consumer Act 2010 Cth for goods purchased in Australia and the Consumer Guarantees Act 1993 NZ for goods purchased in New Zealand 4 Our goods come with guarantees that cannot be excluded under the...

Страница 16: ...or changes in product specifications 2020 Copyright White International Pty Ltd TM WARNING Please be aware that various brands products depicted within this document are subject to trademark patent or...

Отзывы: