Page 5
For technical questions, please call 1-888-866-5797.
Item 59431
Setup
Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual
including all text under subheadings therein before set up or use of this product.
WARNING! High concentrations of vapor in an enclosed area can displace oxygen and create a RISK
OF SUFFOCATION and DEATH.
Always work in a well-ventilated area.
This unit is intended for detecting small, nonhazardous leaks only.
Hook Installation
1. Install the threaded end of the hook into the
threaded port on the top of the smoke machine.
2. Tighten the jam nut with a wrench (not included).
Hook
Jam Nut
Wrench
LED Flip Light Charging
1. Place the LED Flip Light on a dry fireproof surface in
a room where the temperature is from 50–104° F.
Note:
If recharging a newly spent Battery Pack,
allow it to cool completely before charging.
2. Battery Pack must be undamaged, and a Li-Ion
type Battery Pack.
Do not charge a cracked,
open, or leaking Battery Pack, or charge a
non-recommended type of Battery Pack.
3. Plug the Charger into a grounded,
120VAC, 60Hz receptacle.
4. Connect the LED Flip Light to the Charger.
Note:
The Battery Pack’s capacity will increase
somewhat during the first few charging cycles.
A fully discharged Battery Pack will take about 4 to 4-1/2
hours to fully charge.
Recharging the Battery Pack for
more than 4-1/2 hours can damage the battery cells.
5. While charging, the Battery Pack of the LED Flip
Light and Charger may become warm to the touch.
This is normal, and does not indicate a problem.
6. Allow the Battery Pack of the LED Flip Light
to cool completely before using it.