26
MAINTENANCE
Regular maintenance is important for optimal
performance and to reduce wear. Inspect and properly
tighten all parts each time the elliptical is used.
Replace any worn parts immediately.
To clean the elliptical, use a damp cloth and a small
amount of mild soap. IMPORTANT: To avoid damage
to the console, keep liquids away from the console
and keep the console out of direct sunlight.
CONSOLE TROUBLESHOOTING
If the console does not display your heart rate when
you hold the handgrip heart rate monitor, or if the
displayed heart rate appears to be too high or too low,
see step 5 on page 21.
If lines appear in the console display, see 3 on page
24 and adjust the contrast level of the display.
If a replacement power adapter is needed, call the
telephone number on the cover of this manual.
IMPORTANT: To avoid damaging the console, use
only a manufacturer-supplied regulated power
adapter.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted. To adjust the reed
switch, first unplug the power adapter.
Next, using
a standard
screwdriver,
remove the left
Disc (71).
Note: For clarity, the left shield is shown removed in the
drawing at the right.
Locate the Reed Switch (38). Turn the Pulley (19) until
a Magnet (43) is aligned with the Reed Switch.
Next, slightly loosen the indicated M4 x 16mm Screw
(101). Slide the Reed Switch (38) slightly closer to or
away from the Magnet (43), and then retighten the
Screw.
Then, plug in the power adapter and rock the Pulley
(19) forward and backward just enough that the
Magnet (43) passes the Reed Switch (38) repeatedly.
Repeat these actions until the console displays correct
feedback.
When the reed switch is correctly adjusted, reattach
the left disc and plug in the power adapter.