9 Guarantee 

 

Thank  you  for  purchasing  one  of  our  amplifiers.  We 
hope you will be pleased with it. 

 

This  amplifier  is  guaranteed  by  the  dealer  you 
purchased  from  for  12  months  from  the  date  of 
purchase  for  parts  and  labour,  excluding 
shipping.  Valves  are  consumables  and  therefore 
on a 12 months pro-rata  wear basis.  Please keep 
your  receipt  as  proof  of  purchase,  this  will  be 
needed.  

 

All units are individually tested for performance for 48 
hours  before  despatch  to  you.  In  the  unlikely  event 
that you believe the unit is not functioning correctly, it 
may be helpful to contact us first as we may be able 
to assist you. Then we would request that you return 
the item to us for further action. 

 

You  are  advised  to  inform  us  of  any  change  of 
address or change of ownership in order that we may 
keep  you  up  to  date  of  any  upgrades  or 
improvements. Check our website. 

 

Exclusions 

Claims for any  damage to  either amplifiers or valves 
must be reported within three days of receipt. 

 

This  amplifier  is  designed  for  normal  domestic  hi  fi 
use.  It  is  not  guaranteed  for  commercial,  Public 
Address  use,  or  use  in  other  situations.  The 
guarantee  becomes  void  if  the  unit  has  been 
modified in any way not approved by Icon Audio. 

10 Packing Instructions 

It is essential that the original box and packing be 
kept  in  good  condition,  as  this  provides  vital 
protection  during  transit.  Please  do  not  write  on 
box, but use removable labels. 

Should the original 

box  and  packaging  be  lost  or  become  unusable  a 
repacking  charge  of  one  hundred  pounds  will  be 
made.  

 

Re-use  the  supplied  plastic  bag  to  keep  the 
amplifiers clean and free from damp. 

 

The mains lead fits in a foam cut-out underneath 
the amplifier. 

 

Never  ship  with  valve  guard  in  place,  it  will 
almost  certainly  get  damaged,  and  damage 
the  paint  work  of  the  amplifier.  KEEP  THE 
VALVE  GUARD  when  returning  the  amplifier 
for service. 

 

Valves  should  be  removed,  numbered  and 
packed in “Bubblewrap” or similar for protection 
inside the valve cover.  

 

If the amplifier is stored in the box, keep upright. 

 

Do  not  store  in  damp  conditions  as  this  will 
corrode transformer windings etc. 

 

If  the  amplifiers  are  shipped  insurance  is 
desirable due to the high unit value. 

 

 

icon Audio 

UK LTD

 

351 Aylestone Road Leicester  LE2 8TA 

www.iconaudio.co.uk 

Phone +44 (0) 116 244 0593 Cell +44 (0) 778 715 8791 

Fax 0116 244 0593 

2019-08-28 G version 

 

Footnotes 
 

 

1

 PACKAGING. The expected life of your amplifier is approx 20 years, during that time it will need the occasional service and 

valve replacement. The supplied packaging provides essential protection for shipping, and is difficult to replicate. If space is 
short you may find it easier to keep the packaging flat. 

2

 LEFT AND RIGHT AMPLIFIERS are not different, this marking is only for reference. Occasionally amplifiers may not be 

marked in which case customers may find it useful to use their own L R marking. 

3

 Broken valve spigots may often be repaired for new/good/rare valves, especially if the spigot has broken cleanly. Return to 

Icon Audio with £5 for each valve with £5pp. UK/Europe only. 

4

 Accidental swapping of the 6SN7/6SL7 will cause no harm as they are similar, they may be substitute tested in this way, but 

gain and performance will be impaired. 

5

 Most loudspeakers have a range of impedance from as low as 2Ω to as high as 20Ω, so the correct setting is your preference 

in your system in your room. Generally the 4Ω taps will sound a little quieter with slightly more bass weight. The 8Ω taps 
being slightly louder with a lighter balance. In practice most customers choose the 8Ω taps. The SENSITIVITY and 
TRIODE/UL switch will also combine to affect the sound. 

6

 STANDBY SWITCH. Should be “UP” before switching on. And “UP” before switching off. This prevents power surges 

damaging the cold cathodes. Valves last longer if they are given a chance to warm up before applying power. The standby 
switch also allows you to save power for short periods, with the amplifier ready to start instantly. Occasional “switch on” 
without using the standby switch will not damage the valves or amplifier any more than amplifiers without this facility. 
Engineers Notes 
 
  

Содержание MB90 MK IIm

Страница 1: ...or feel that we have missed anything out Hi fi reproduction is a long chain of events that includes the recording editing mixing etc before being transferred to a medium such as LP Digital etc before...

Страница 2: ...ck input Output Valve Bias level v Sound Quality Channel Balance Valve Microphony Valve Seating Hum level mv RF Test LED brightness Serial No sticker and recorded Mains voltage 110 230 240V IEC Mains...

Страница 3: ...isible orange glow from the cathode heaters With the pre amp volume control set to minimum there should be no sound coming from the speakers except a barely discernable hum If there are any unpleasant...

Страница 4: ...the speakers close together If correct you should hear plenty of bass if not reverse the terminals for one channel only either at the amp or speaker You will now hear more or less bass The higher bas...

Страница 5: ...ments should be 3 Amp anti surge 5a USA The fuse in the wall plug should be a 3 or 5 amp fuse although unlikely to fail this should be checked if the amplifier fuse is OK No sound Have you selected th...

Страница 6: ...break do not bend excessively to the side The MB90m MK II is specifically designed to use KT120 or KT150 valves Use of the lower rated KT88 6550 KT90 etc is not recommended as the lower ratingings ma...

Страница 7: ...10w RMS KT150 120 Ultralinear 60w RMS KT150 120 Triode mode Signal to noise level 95db Freq response 20Hz 20kHz or 0 1db Power bandwidth 3db 10Hz 30kHz 0 1 THD typical 8w 0 015 1w 1khz Custom hand wou...

Страница 8: ...ide the valve cover If the amplifier is stored in the box keep upright Do not store in damp conditions as this will corrode transformer windings etc If the amplifiers are shipped insurance is desirabl...

Страница 9: ...attached to the base If the fuse blows again a VARIAC or variable transformer will be useful to operate the amplifier on reduced power in order the trace the fault or overload Make sure the bias for t...

Отзывы: