icon Audio MB90 MK IIm Скачать руководство пользователя страница 3

Page 3 

IMPORTANT READ THESE NOTES THROUGH FIRST! 

 

2 QUICK SET UP GUIDE  

 

1  Unpack  unit  carefully

.  Make  sure  that  it  is  in  good 

condition. If not report to Icon Audio. It is important that 
you keep the packaging for warranty/service return.

1

 

 

2  If  Necessary  fit  the  valves,  or  check  that  they  are 
firmly  in  place.  Fit  the  valves  according  to  the 
numbers  written  on  the  base,  normally  L  1-5  and  R 
1-5  as  printed  on  the  copper  plate. 

The  KT150/120s 

should  be  fitted  first  to  the  two 

REAR

  sockets  (the  two 

sockets  nearest  the  transformers). To  avoid  damage  to 
the  valves  hold  the  valves  as  close  to  the  base  as 
possible 

NOTE  THE  “LEFT”  and  “RIGHT”  KT150/120 
orientation on each amplifier. Also keep the left and 
right  amplifier  valves  separate.  The  right/left 
amplifiers can be identified by the red or black ring 
on the input sockets at the rear.

2

 

Be  careful  to  note  the  correct  orientation  of  the 
central “spigot” between the pins otherwise damage 
could occur. 

3

 

The  small  valves  should  be  gently  &  firmly  pushed  into 
place.  The  6SL7  (6188)  is  fitted  to  the  right  hand  base 
(the same side as the triode switch) and the 6SN7 to the 
left  hand  base  (the  same  side  as  the  standby  switch). 
The 0D3 should be in the centre. 

NOTE:  The  KT150/120

’s  and  6SL7/6SN7  are  NOT 

interchangeable!  This  will  result  in  damage  and 
could be dangerous.

4

 

 

3  Connect  to  source  unit

,  e.g.  Phono  pre  amp, 

Passive pre amp etc via appropriate phono sockets. Set 
L & R SENSITIVITY switches on the rear to High (H) or 
Low (L) as required, see 6a. 

4  Connect  speaker  terminals

 

use  “0”  &  “8  ohm” 

terminals  unless  you  have  4  ohm  speakers  (see  P5) 
Make  sure  that  the  polarity  is  correct.  (See  speaker 
connections  chapter  3

).  If  ‘bi-wiring’  both  ‘common’ 

should  go  to  the  black  terminal 

and  both  ‘positive’  (or 

red) should go to the red terminals. 

5

 

 

5  Connect  to  mains

  supply  using  supplied  IEC  mains 

lead  to  230v  supply. 

If  for  some  reason  the  welded 

plug  must  be  removed,  please  remove  plug  fuse 
and dispose of immediately.

 (They can be a danger to 

children if plugged in). The replacement plug should be 
wired  in  the  following  way  Brown  to  Live  terminal,  Blue 
to Neutral terminal and Green/Yellow to Earth terminal. 

 

Before switching on make sure that the “standby 

switch” is in the “up” position. 

6

 

SWITCH  ON!

  Leave  for  at  least  60  seconds  for  the 

valves  to  warm  up,  and  then 

push the “standby” switch 

into  the  “down”  position.  The  amplifier  should  now  be 
working. Most valves should have a visible orange glow 
from  the  cathode  heaters.  With  the  pre  amp  volume 
control  set  to  minimum  there  should  be  no  sound 
coming  from  the  speakers  except  a  barely  discernable 
hum.  If  there  are  any  unpleasant  sounds  coming  from 
the 

speakers,  switch  off  and  refer  to  the  ‘Trouble 

Shooting’ section or contact Icon Audio. We recommend 

you  switch  to  “standby”  when  switching  off,  (to  be 
ready for your next session). 

 

6a High/Low Sensitivity Switch (on rear) 

The  LOW  sensitivity  position  is  designed  to  work  with 
normal  valve  and  solid  state  pre  amplifiers,  giving  the 
best  damping  factor  for  “difficult  load”  speakers, 
(normal feedback). 
The HIGH sensitivity position is for “Passive” pre-amps 
(without  gain)  or  devices  with  a  volume  control  (our 
PS1/PS3  phono  stage,  MP3,  “i  Phone/Pod”  etc). 
Purists  may  prefer  this  low  feedback  sound.  Feel  free 
to change and choose your preference. 

 

7 Your unit should now be functioning

. If not check 

wiring  again.  Do  not  operate  at  a  high  volume  for  the 
first  five  minutes  to  allow  the  valves  to  warm  up 
properly. 

 

All these things are normal for valve amplifiers: 

A, Valves can get very hot, BEWARE! 
B, The power transformer cover will get quite warm 
C, The amplifier may smell a little for a few hours. 
D, Mobile phon

e ‘breakthrough’ is normal. 

E, Valves may make a ‘tinkling’ sound when warming 
up and cooling down. 
F,  One  channel  may  come  on  before  the  other  at 
switch on. 
G, 

There may be a ‘click’ when switching off. 

H, T

he occasional “click” or “pop” is normal. 

 

8 Health and Safety

. The valves when operating have 

high  surface  temperatures.  Keep  out  of  reach  of 
children  and  pets.  The  use  of  the  supplied  guard  is 
recommended  in  these  circumstances.  Always  unplug 
when  making  adjustments. 

Like  all  amplifiers  there 

are  potentially  lethal  high  voltages  inside  (over 
500v  DC),  which  when  switched  off  can  take 
twenty minutes to discharge!

 Do not remove bottom 

panel unless you are a competent engineer. There are 
no  user  serviceable  parts  inside. 

Like  other 

household  electrical  appliances  do  not  leave 
unattended  whilst  switched  on.

  Do  not  adjust  the 

KT150/120  bias  pre  sets  without  reference  to  the 
manual.  Incorrect  adjustment  could  cause  the  valves 
to overheat,  with resulting

 in damage to valves and 

amplifier.  

 

Bias Adjustment: 
The  bias  adjustment  is  factory  set.  No  initial 
adjustment  should  be  necessary.  But  it  is 
suggested  that  you  test  after  shipping  to  ensure 
the correct operation. 

To  maintain  the  best  performance  of  the  amplifier 
you  should  check  the  bias  of  the  output  valves 
regularly  (say  once  a  month).  Full  details  will  be 
found in section 6. 
For use of output valves other than KT150/120 see 
section 6. 

Содержание MB90 MK IIm

Страница 1: ...or feel that we have missed anything out Hi fi reproduction is a long chain of events that includes the recording editing mixing etc before being transferred to a medium such as LP Digital etc before...

Страница 2: ...ck input Output Valve Bias level v Sound Quality Channel Balance Valve Microphony Valve Seating Hum level mv RF Test LED brightness Serial No sticker and recorded Mains voltage 110 230 240V IEC Mains...

Страница 3: ...isible orange glow from the cathode heaters With the pre amp volume control set to minimum there should be no sound coming from the speakers except a barely discernable hum If there are any unpleasant...

Страница 4: ...the speakers close together If correct you should hear plenty of bass if not reverse the terminals for one channel only either at the amp or speaker You will now hear more or less bass The higher bas...

Страница 5: ...ments should be 3 Amp anti surge 5a USA The fuse in the wall plug should be a 3 or 5 amp fuse although unlikely to fail this should be checked if the amplifier fuse is OK No sound Have you selected th...

Страница 6: ...break do not bend excessively to the side The MB90m MK II is specifically designed to use KT120 or KT150 valves Use of the lower rated KT88 6550 KT90 etc is not recommended as the lower ratingings ma...

Страница 7: ...10w RMS KT150 120 Ultralinear 60w RMS KT150 120 Triode mode Signal to noise level 95db Freq response 20Hz 20kHz or 0 1db Power bandwidth 3db 10Hz 30kHz 0 1 THD typical 8w 0 015 1w 1khz Custom hand wou...

Страница 8: ...ide the valve cover If the amplifier is stored in the box keep upright Do not store in damp conditions as this will corrode transformer windings etc If the amplifiers are shipped insurance is desirabl...

Страница 9: ...attached to the base If the fuse blows again a VARIAC or variable transformer will be useful to operate the amplifier on reduced power in order the trace the fault or overload Make sure the bias for t...

Отзывы: