9
26
■
Mounting the EX-2714 scanner unit
D
Location
The scanner unit is designed to be weatherproof and
completely watertight. Select a place for installation
which meets the following important conditions.
q
The scanner unit must be near the boat’s center line
and have a good view in every direction. Be sure
there are no objects in the surrounding area which
will intercept the scanning beam.
w
KEEP
the scanner unit away from any smoke-
stacks. Smoke can damage the unit.
e
When the boat is equipped with a radio directional
finder (RDF) system, keep the scanner unit at least
2 m (6.6 ft) away from any RDF antenna.
• Radiation from the scanner unit can affect the measure-
ment data of RDF equipment.
r
The unit should be placed as high as possible on
the boat to obtain best performance with maximum
range.
t
If you install two or more radar in one boat, install
one above, and one below.
y
The mounting surface must be parallel with the
boat’s waterline.
u
If the height is insufficient to install the scanner unit,
build a special frame for installation.
D
Mounting
q
Drill four holes of 12 mm (
1
⁄
2
in) in diameter using
the template.
w
If the mounting surface or platform is metal, apply
sealing compound around the holes to prevent cor-
rosion and to waterproof the unit.
e
Fix the scanner unit to the selected position with
bolts of 10 mm (
3
⁄
8
in) in diameter, with flat and
spring washers. The supplied bolts are two lengths:
25 mm (1 in) or 50 mm (2 in).
CAUTION: SECURE
the four bolts tightly.
WARNING:
BE SURE
[POWER] is
OFF
when-
ever you are working with the scanner unit.
607 (23
29
⁄
32
)
45.5 (1
13
⁄
16
) 150.5 (5
15
⁄
16
)
243 (9
9
⁄
16
)
90.5 (3
9
⁄
16
)
90.5 (3
9
⁄
16
)
Ship’s bow direction
Ship’s bow direction
Unit: mm (in)
INSTALLATION AND CONNECTIONS
MR-1000R2_T2.qxd 04.2.24 10:22 Page 26